N7201A654E.pdf - 第72页
NPM- TT2 EJM1EE-MB-02 T-02 Part Pickup Error Stock Parts Empty Parts Empty Stop Parts Empty Occurs Parts Empty Warning Error Messag e Troubleshooting 2-1-3 Single stop errors 1 Error Code Error Message Cause Inspection a…

NPM-TT2 EJM1EE-MB-02T-02
DC power FAN alarm
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fan of the DC power
stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40167
2-1-2-46

NPM-TT2 EJM1EE-MB-02T-02
Part Pickup Error
Stock Parts Empty
Parts Empty Stop
Parts Empty Occurs
Parts Empty Warning
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 1
Error Code
Error Message
Cause Inspection and Solution
Components are running
short.
(Single stop error occurred.)
Supply the components.
40302
Components have run out.
(Single stop error occurred.)
Supply the components.
40303
Components have run out.
(Single stop error occurred.)
Supply the components.
40304
Stocked components have
run out.
(Single stop error occurred.)
Supply the components.
40305
Any of the following causes
is likely:
1) Invalid component data
height.
2) Improper component feed.
3) Incorrect pickup position.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Correct the component data.
2) Replace the feeder.
3) Choose [Arrange] - [Parts
prepare] - [Feeder] - [Pickup
position] and perform teaching of
the component pickup position.
40306
2-1-3-1

NPM-TT2 EJM1EE-MB-02T-02
Parts Standing Error
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper components are
set.
2) Incorrect component data
(component dimensions^
etc.)
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Set the correct components.
2) Check the component data
(component dimensions, etc.).
40307
Any of the following causes
is likely:
1) Improper components are
set.
2) Incorrect component data
(component dimensions^
etc.)
3) Component picked up
sideways.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Set the correct components.
2) Check the component data
(component dimensions, etc.).
3) Check the pickup condition.
40308
2-1-3-2