N7201A654E.pdf - 第260页
NPM- TT2 EJM1EE-MB-02 T-02 Camera IF board Device driver error IspBox SubSys Time out error IspBox SubSys Error IspBox SubSys Pr oduction data error IspBox SubSys Pr oduction data error Error Messag e Troubleshooting 2-1…

NPM-TT2 EJM1EE-MB-02T-02
IspBox SubSys Production
data not evolved error
IspBox SubSys Production
data evolution error
IspBox SubSys Mark
correction error
IspBox SubSys Inspection
template data make error
IspBox SubSys State
abnormal
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Application condition is
abnormal.)
Restart the machine. If the error
persists, contact PFSC.
1891
Improper procedure was
taken in software processing.
(Failed to create inspection
template data.)
Restart the machine. If the error
persists, contact PFSC.
1892
Improper procedure was
taken in software processing.
(Failed to register mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1893
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1894
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1895
2-1-4-87

NPM-TT2 EJM1EE-MB-02T-02
Camera IF board Device
driver error
IspBox SubSys Time out
error
IspBox SubSys Error
IspBox SubSys Production
data error
IspBox SubSys Production
data error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 45
Error Code
Error Message
Cause Inspection and Solution
Invalid content was found in
the production data.
(Invalid production data.)
Create the production data again.
Then, download the production data
again.
1896
Failed to get the view data.
(Failed to get the view data.)
Check the applicable components
for inspection in the production data
and download the data again.
1897
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1898
Improper procedure was
taken in software processing.
(Timeout occurred in
software processing.)
Restart the machine. If the error
persists, contact PFSC.
1899
Improper procedure was
taken in software processing.
(Camera IF board driver
aborted.)
Restart the machine. If the error
persists, contact PFSC.
1900
2-1-4-88

NPM-TT2 EJM1EE-MB-02T-02
Camera IF board Camera
parameter set error
Camera IF board Light
spot correction table set
error
Camera IF board Binary
table set error
Camera IF board Camera
capture parameter error
Camera IF board
Initialization error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Capture board could not be
initialized.
(Failed to initialize the
camera IF board.)
Check the connection of the camera
link cable between the inspection
head and inspection box.
1901
Improper procedure was
taken in software processing.
(Failed to obtain the capture
parameter.)
Restart the machine. If the error
persists, contact PFSC.
1902
Improper procedure was
taken in software processing.
(Failed to set the binary table
of the camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1903
Improper procedure was
taken in software processing.
(Failed to set the light spot
correction table of the
camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1904
Improper procedure was
taken in software processing.
(Failed to set the camera
parameters of the camera IF
board.)
Restart the machine. If the error
persists, contact PFSC.
1905
2-1-4-89