N7201A654E.pdf - 第81页
NPM- TT2 EJM1EE-MB-02 T-02 Nozz le Recognition Er ror Nozzle Fall Solutions to errors Error Code Error Message Cause Inspection and Solution Any of the following causes is likely: 1) Nozzle came off during pickup or moun…

NPM-TT2 EJM1EE-MB-02T-02
Chip Eject Error
Part Drop
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 5
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Component dropped
during after recognition
before it was mounted.
2) Nozzle or filter clogged.
3) Component is not
securely picked up by the
nozzle.
4) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove dropped component and
restart the machine.
2) Clean the nozzle and filter.
3) Remove the component and
restart production.
4) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40327
Any of the following causes
is likely:
1) Recognition error
component failed to be
ejected to the eject box.
2) Nozzle or filter clogged.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove the remaining
components from the nozzles and
restart the machine.
2) Clean the nozzle and filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40328
2-1-3-9

NPM-TT2 EJM1EE-MB-02T-02
Nozzle Recognition Error
Nozzle Fall
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Nozzle came off during
pickup or mounting.
2) Filter is clogged.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the nozzle and attach it if it
came off.
2) Clean the filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40329
Recognition error occurred
due to dirty mark^ etc.
(Single stop error occurred.)
Check if the time-lapse change
calibration mark is not dirty. Clean
the mark if dirty.
40330
2-1-3-10

NPM-TT2 EJM1EE-MB-02T-02
Pickup Pos Recog Error
Nozzle Change Error
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 6
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper shutter action at
nozzle changer
2) Improper cylinder action
3) Deformed or bent nozzle
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Choose [Machine] - [Adjust] -
[Head] - [Nozzle exchange] and
open/close the nozzle changer.
Check for proper movement. If
stopped or caught on the way,
perform cleaning.
2) Replace the cylinder.
3) Replace the nozzle.
40331
Component is out of
camera's view.
(Single stop error occurred.)
Take measures in the following
order.
1) Move the camera to the center
position of the component using
the inching function and press the
[Recognize] button.
2) If the recognition error occurs
again, move the camera to the
center position of the component
using the inching function and
press the [Manual set]
button.[Manual set]: Save the
inching amount as the offset.
40332
2-1-3-11