N7201A654E.pdf - 第220页
NPM- TT2 EJM1EE-MB-02 T-02 Motion Incomplete Origin Return Uncomplete d Power On Error Error Messag e Troubleshooting 2-1-4 Emergency stop errors 25 Error Code Error Message Cause Inspection and Solution Origin return or…

NPM-TT2 EJM1EE-MB-02T-02
Hardware Detection
Motion Incomplete
Interfere Check Error
Continuous Operation
Setting Error
Software Limit Over Error
Servo Amplifier Detect
Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Power to the machine may
be unstable.
(Instantaneous stop detected
in servo amplifier.)
After checking the power, if the error
persists, contact PFSC.
1636
Improper procedure was
taken in software processing.
(Incorrect parameter setting
values.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1637
Improper procedure was
taken in software processing.
(Incorrect parameter setting
values.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1638
Improper procedure was
taken in software processing.
(Interference may occur.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1639
The command issued by the
machine timed out. Head
motor has not finished the
operation.
(Head fails to move
properly.)
Turn the machine power back ON
and start production. Then, check
the situation of the error occurred
and error message, and contact
PFSC.
1641
2-1-4-47

NPM-TT2 EJM1EE-MB-02T-02
Motion Incomplete
Origin Return
Uncompleted
Power On Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 25
Error Code
Error Message
Cause Inspection and Solution
Origin return or movement
command was issued
without turning the power ON.
Emergency stop switch may
have been pressed or cover
may be opened.
(Head fails to move
properly.)
Turn the machine power back ON
and start production. Then, check
the situation of the error occurred
and error message, and contact
PFSC.
1642
Movement command was
issued before the axis
returned to origin.
(Head axis did not properly
return to origin. )
Close the error screen and perform
origin return. Then, restart
production. Check the situation of
the error occurred and error
message, and contact PFSC.
1643
Movement command was
issued before positioning
was completed.
(Head fails to move
properly.)
Close the error screen and perform
origin return. Then, restart
production. Check the situation of
the error occurred and error
message, and contact PFSC.
1644
2-1-4-48

NPM-TT2 EJM1EE-MB-02T-02
Parameter Error
Command Error
Emergency Stop
(Controller)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Emergency stop signal was
input to the head unit.
(Head axis stopped.)
1) Turn the emergency stop switch
clockwise to reset.(One position
each at front side and rear side)
2) If the machine fails to be restored
even after pressing the emergency
stop switch, the switch may be
broken.Contact PFSC.
1645
Improper procedure was
taken in software processing.
(Unsupported command in
the head command issued.)
Close the error screen and perform
origin return. Then, restart
production. Check the situation of
the error occurred and error
message, and contact PFSC.
1646
Improper procedure was
taken in software processing.
e.g.: 2 has been set although
available parameter is 0 or 1.
(Invalid parameter setting.)
Close the error screen and perform
origin return. Then, restart
production. Check the situation of
the error occurred and error
message, and contact PFSC.
1647
2-1-4-49