N7201A654E.pdf - 第122页
NPM- TT2 EJM1EE-MB-02 T-02 Parts Re cognition Error Parts Re cognition Error Error Messag e Troubleshooting 2-1-3 Single stop errors 26 Error Code Error Message Cause Inspection and Solution Mismatch occurred in the inte…

NPM-TT2 EJM1EE-MB-02T-02
Ionizer Alarm
Constant check error
APC-MFB:
File I/O error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in MFB
related file input and output
process.(Display the kind of
the following error) 1:Data
out of range 2:No applicable
parts error 3:File format
error(AOI check result)
4:File format error(NPM
mount position correct
record ) 5:File access error^
other
(Single stop error occurred.)
・Error1,2,3,4Please confirm the
situation of the error occurred and
contact PFSC.・Error51)Please
confirm the communication status
between LNB and MC.
2)Please confirm the situation of the
error occurred and contact PFSC.
40485
Error occurred in the
constant check action.
(Single stop error occurred.)
1)Please confirm the constant
checker unit or parts status.
2)Please confirm if the set parts is
correct constant parts.
40486
Detected the ionizer alarm.
(Single stop error occurred.)
Please settle the problem of ionizer
alarm and resume the production.
40488
2-1-3-50

NPM-TT2 EJM1EE-MB-02T-02
Parts Recognition Error
Parts Recognition Error
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 26
Error Code
Error Message
Cause Inspection and Solution
Mismatch occurred in the
internal processing of
recognition function.Error
occurred in the parameter
area in the recognition
processing.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43001
Mismatch occurred in the
internal processing of
recognition function.Error
occurred in the parameter
area in the recognition
processing.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43002
2-1-3-51

NPM-TT2 EJM1EE-MB-02T-02
Parts Recognition Error
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Mismatch occurred in the
internal processing of
recognition function.Error
occurred in the parameter
area in the recognition
processing.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43003
Mismatch occurred in the
internal processing of
recognition function.Error
occurred in the parameter
area in the recognition
processing.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43004