N7201A654E.pdf - 第292页
NPM- TT2 EJM1EE-MB-02 T-02 2-1-4 -120

NPM-TT2 EJM1EE-MB-02T-02
Check error before axis
action
PartsDetectAfterMounting(
VLCOutputData out of
validRangeErr)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Return the output value
which exceeds allowable
range from VLC unit.
(Error occurred in parts
detect after mounting.)
1. Please confirm that there are no
parts dropped on the PCB.2. Please
confirm that there is no dust(Parts
etc.) on the setting side of nozzle
holder set in nozzle changer.3.
Please confirm there is no dust
adhered to VLC unit.4. If it can't be
solved by above 1,2,3, please
calibrate the VLC unit.
2226
According to the soft
process^ move to incorrect
position.
(Error has been detected in
the check before axis action.)
Please start the production again
after confirming the production PCB.
If the error persists, contact PFSC.
2227
2-1-4-119

NPM-TT2 EJM1EE-MB-02T-02
2-1-4-120

NPM-TT2 EJM1EE-MB-02T-02
Solutions to errors
2-2-1
Error
Message
Troubleshooting
2-2
Warning message 1
Code
Message
Cause Solution
PCB temperature
warning
The operating temperature at
the operation switch board is
close to reaching its
specified upper limit.
Check the ambient temperature
around the machine.
If the warning continues to appear,
contact PFSC.
2216
Bad head occur
When the error rate of each
head has exceeded the bad
head error rate (action
parameter), the applicable
head will be set as a bad
head and the placement
motion will continue.
1.Check the bad head conditions.
2.After the problem has been
resolved, cancel the bad head
settings on the bad head setting
screen.
3138
Pickup sequence
change
If a simultaneous pickup
failure has occurred in the
sequence of pickup specified
as simultaneous pickup, the
warning appears.
If the warning continues to appear,
identify the cause (pickup position,
nozzle, etc.) of the simultaneous
pickup failure.
3905
If a warning message appears while you use the machine, check the following causes and solutions.