Portal 00197 973 - 10 / 02 , 2016 8- 10 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al Access: • Open the maintenance d oor on t he right side. If t he Z axis is n o t on the rear, softly push it to t he rear to gai…

00197973-10 / 02 , 2016 Portal
SIPLACE Mat. Tower Storage Service Manual © ASM 8-9
8.3.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key Nr. 2, 2.5
Auxiliary Material: none
Spare parts:
03124522
-01, door open/close sensor
Time needed
Schedule around 10 minutes for this task.
8.3.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled
and trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
• NO item must be unloaded.
Machine operating
condition:
• Shut down
Main electrical power:
• The Main Switch must be switched off.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.

Portal 00197973-10 / 02 , 2016
8-10 © ASM SIPLACE Mat. Tower Storage Service Manual
Access:
• Open the maintenance door on the right side. If the Z axis is not on
the rear, softly push it to the rear to gain access to the portal.
8.3.4 Exchange steps
Step 1
Unplug the electrical connection of the sensor.
Step 2
Remove the two screws and the whole sensor
holder.

00197973-10 / 02 , 2016 Portal
SIPLACE Mat. Tower Storage Service Manual © ASM 8-11
Step 3
Exchange the old sensor with a new one.
Step 4
Mount the sensor holder on its place and plug the electrical connectors as described in step 2 and
1.
Step 5
Plug in the power connector and switch on the machine.
Assure that noone is manipulating the software whilst you are inside the machine.
Step 6
Setup the position of the sensor that following
conditions are fulfilled:
Fully open the portal door. The red LED must be
on, meaning the sensor is activated.
Fully close the portal door. The red LED must be
of, meaning the senso
r is deactivated.
Step 7
Remove all tools and close the doors of the machine.
Connect the compressed air supply.
Initialize the machine by means of the software.