Service Door Monitoring 00197973-10 / 02 , 2016
12-8 © ASM SIPLACE Mat. Tower Storage Service Manual
Mounting Sensor and Magnet, right side of the machine
Fix the sensor (part with the 4500 mm cable) on
the right side of the machine, on the door with
the locking mechanism.
Tighten the screws and make sure again the
screws a
re flush with the door surface.
Mount 2 adhesive pads (1) as shown on picture.
Route the cable as shown on picture and route it
through the hole of the door the same way as on
the left side of the machine. Fix the cable on the
pads by means of a cable ti
e.
Fix the magnet (part without cable) on the
opposite door without locking mechanism.
Tighten the screws and make sure again the
screws are flush with the door surface.

00197973-10 / 02 , 2016 Service Door Monitoring
SIPLACE Mat. Tower Storage Service Manual © ASM 12-9
Routing of the Sensor Cable
Starting on the right sid
e of the machine, see the
overview picture to get an idea of the routing of
the sensor cable.
Route the cable through the cable bushing
and
through the slot of the chassis (see picture).
Make sure the cable has a loop after the bushing
for the length compensation (opening and
closing the door).
If cabling a SIPLACE Material Tower Regular, skip
this step.
If cabling a SIPLACE Material Tower Large,
mount an adhesive pad on the left side on the
most left rack (1).
Fix the cable by means of a cable tie.

Service Door Monitoring 00197973-10 / 02 , 2016
12-10 © ASM SIPLACE Mat. Tower Storage Service Manual
Rout the cable all along the 230 V cable and fix it
by using cable ties together with the 230 V cable
on the existing pads (1).
Going to the left side of the machine, route the
cable of the left door sensor through the
bushing. Make sure the cable has a loop after the
bushing for the length compensation (opening
and closing the door).
Route both sensor cables along the 230 V cable
and use the existing pads to fix the cables. Pay
attention to a proper cabling for better
recognition of right and left sensor cable
afterwards or mark the cables at the end.
Check the position of the edge protector (1), so
that the cables are protected
properly.
During preparation of the electrical cabinet, the
sensor cables can be put away as shown on
picture.