00197973-10_SM_MaterialTower.pdf - 第234页

Option Air Dryer 0019797 3 - 10 / 02 , 2016 11 - 20 © ASM SIPLACE Mat. Tower St ora ge Serv ice Manu al Swap the 4 m m hose connect or. Swap the 15 m m hose connec tor. Step 4 Remove the dry a ir output including the sil…

100%1 / 274
00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-19
11.3.4 Exchange steps
Step 1
Unplug all three air connection hoses.
Step 2
The four screws holding the air dryer are located
at the back side of the panel. Unscrew them
while securely holding the membrane dryer.
Step 3
Lay the old an new membrane dryer down on a table. In this step remove two connections from
the old dryer and assemble them to the new dryer.
Option Air Dryer 00197973-10 / 02 , 2016
11-20 © ASM SIPLACE Mat. Tower Storage Service Manual
Swap the 4 mm hose connector.
Swap the 15 mm hose connector.
Step 4
Remove the dry air output including the silencer
by loosening the adaptor. It may help when
removing the four screws of the holding first.
00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-21
Remove the compressed air input including the
connector by loosening the adaptor. It may help
when removing the four screws of the holding
first.
If not already done, remove all eight screws and
the holding.
Step 5
Assemble the parts which have been removed in step 4 on the new membrane dryer. Follow the
reversed disassembling order of step 4.
Step 6
Assemble the new membrane dryer. The four
screws holding the air dryer are l
ocated at the