00197973-10_SM_MaterialTower.pdf - 第233页
0019797 3 - 10 / 02 , 2016 Option Air Dryer SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 11 - 19 11.3.4 Exchange steps Step 1 Unplug all three a ir connection hoses. Step 2 The four screws ho lding the air dryer a…

Option Air Dryer 00197973-10 / 02 , 2016
11-18 © ASM SIPLACE Mat. Tower Storage Service Manual
Spare parts:
03124533
-01, membrane air dryer
Time needed
Schedule around 15 minutes for this task.
11.3.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled
and trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
• NO item must be unloaded.
Machine operating
condition:
• Shut down
Main electrical power:
• The Main Switch must be switched off.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.
Access:
• Open the left side door of the machine, where the electrical unit and
the air dryer is located.

00197973-10 / 02 , 2016 Option Air Dryer
SIPLACE Mat. Tower Storage Service Manual © ASM 11-19
11.3.4 Exchange steps
Step 1
Unplug all three air connection hoses.
Step 2
The four screws holding the air dryer are located
at the back side of the panel. Unscrew them
while securely holding the membrane dryer.
Step 3
Lay the old an new membrane dryer down on a table. In this step remove two connections from
the old dryer and assemble them to the new dryer.

Option Air Dryer 00197973-10 / 02 , 2016
11-20 © ASM SIPLACE Mat. Tower Storage Service Manual
Swap the 4 mm hose connector.
Swap the 15 mm hose connector.
Step 4
Remove the dry air output including the silencer
by loosening the adaptor. It may help when
removing the four screws of the holding first.