00197973-10_SM_MaterialTower.pdf - 第206页

Electronics 0019797 3 - 10 / 02 , 2016 9-8 © ASM SIPLACE Mat. Tower S tor ag e Service Ma nual Spare part num ber: 03126679 - 01 Before starting the maintenance, read the Safety instructions carefully. 9.3.2 Tools, Mater…

100%1 / 274
00197973-10 / 02 , 2016 Electronics
SIPLACE Mat. Tower Storage Service Manual © ASM 9-7
Step 2
Using the screwdriver, push the clip down that
secures the power supply to the hat rail.
Remove the power supply.
Step 3
Take the new power supply and push it firmly on
the hat rail. Make sure the clip is secured and the
position is fixed.
Fasten all cable connection in their correct slots.
Step 4
Remove all tools, plug in the power connector and switch on the machine.
By means of the voltmeter, measure the output voltage of the power supply. It should be 24V
Step 5
Close the door of the machine and Initialize the machine by means of the software.
9.3 48V Supply
9.3.1 Introduction
This modification instruction describes how to change the 48V power supply on SIPLACE Material
Tower.
Electronics 00197973-10 / 02 , 2016
9-8 © ASM SIPLACE Mat. Tower Storage Service Manual
Spare part number: 03126679-01
Before starting the maintenance, read the Safety instructions carefully.
9.3.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Slotted screw driver nr. 2
Voltmeter
Auxiliary Material: none
Spare parts:
03126679
-01, 48V power supply
Time needed
Schedule around 10 minutes for this task.
9.3.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
Stored items do not have to be unloaded.
Machine operating
condition:
Shut down
00197973-10 / 02 , 2016 Electronics
SIPLACE Mat. Tower Storage Service Manual © ASM 9-9
Main electrical power:
Equipment disconnected from power supply system. Fully
disconnect the mains power cable and secure against
unintentional plugging.
Compressed air /
Nitrogen (if used):
Equipment disconnected from nitrogen.
Access:
Open the door on the left side of the machine.
The electrical units are located in the bottom right corner.
9.3.4 Exchange steps
Step 1
Carefully loosen the cable tie holder that is
sticked to the electrical base plate.
Step 2
Using the screwdriver, push the clip down that
sec
ures the power supply to the hat rail.
Step 3
Unscrew all cable connections on the top and the bottom of the power supply.
Make sure to label the cables or mark their proper slot in the power supply.
Remove the power supply.