X Axis 0019797 3 - 10 / 02 , 2016 4- 24 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al Loosen and rem ove the two cables (r ed/black) from the connect or of the old and of the new hybrid cable by means of a s crewdr…

100%1 / 274
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-23
Check again for proper cable routing illustrated
on the picture.
Tighten the screws of the cable clamping (1).
Fix the new hybrid cable by using cable ties (2).
Finalize cable exchange
Loosen the shield terminals by hand and remove
the cables of the hybrid cable which has to be
exchanged. It is possible that other cables use
the same shield terminal, if so do not remove
them.
Remove the two power cables (48 V) from the
connector which has to be exchanged
(brown/white) by means of a screwdriver.
Be careful, between the
wires a remaining
voltage (< 48 V) can still be present.
Loosen and remove the two interlinked
connectors.
X Axis 00197973-10 / 02 , 2016
4-24 © ASM SIPLACE Mat. Tower Storage Service Manual
Loosen and remove the two cables (r
ed/black)
from the connector of the old and of the new
hybrid cable by means of a screwdriver (because
of many other cables using the same connector
it is easier to exchange the two cables than the
whole connector).
Place the two cables (red/black) of the
new
hybrid cable at exact the same connector
positions (black at pin 7 / red at pin 10)
Plug in and lock the two interlinked connectors
of the new hybrid cable (the connector with the
larger number of cables in the upper slot, the
one with less number of cables in the lower slot).
Re
-place the two power cables (48 V)
(brown/white) by means o
f a screwdriver (same
position as power cables of adjacent connector,
pin 22 and 24).
Clamp the cables of the new hybrid cable with
the shield
terminals and tighten the screws by
hand. It is possible that other cables use the
same shield terminal, if so re
-connect them as
well.
Closing tasks
Make sure all the cables are fitted correctly. They should not touch the door if closed.
Make sure free movement is allowed for the hybrid cable along the whole driving range of the
X axis (no collision, no touching the chassis).
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-25
Finalize exchange steps
Remove all tools, attach all previously removed covers and close the doors of the machine.
Plug in the power connector and switch on the machine.
Initialize the machine by means of the software.