00197973-10_SM_MaterialTower.pdf - 第36页
HMI 0019797 3 - 10 / 02 , 2016 3-2 © ASM SIPLACE Mat. Tower S tor ag e Service Ma nual Time needed Schedu le around 15 minutes fo r this task. 3.1.3 Prere quisites For a safe an d efficient maintena nce, the following pr…

00197973-10 / 02 , 2016
SIPLACE Mat. Tower Storage Service Manual © ASM 3-1
3 HMI
3.1 GUIK with support
3.1.1 Introduction
This modification instruction describes how to change the touch screen (GUIK) electronic with its
support on machine SIPLACE Material Tower.
Spare part number: 03124523-01
Before starting the maintenance, read the Safety instructions carefully.
3.1.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key nr. 3
Phillips screwdriver nr. 1
Auxiliary Material: none
Spare parts:
03124523
-01, GUIK with support

HMI 00197973-10 / 02 , 2016
3-2 © ASM SIPLACE Mat. Tower Storage Service Manual
Time needed
Schedule around 15 minutes for this task.
3.1.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
• Stored items do not have to be unloaded.
• If shelves are positioned directly above the portal, it can be necessary
to unload their stored items and to remove them for better access to
the GUIK electronics.
Machine operating
condition:
• Shut down
Main electrical
power:
• Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.
Access:
•
Open both doors of the machine.
3.1.4 Exchange steps
Check working space
Have a short look on the exchange procedure
below and check if there is enough space
around the portal to do the work (above or
below, depending on the exch
ange procedure).
If there is not enough space, unload the
obstructive items and remove their shelves.
Make a note of the exact position of shelves and
items for an exact refit after the exchange
procedure.

00197973-10 / 02 , 2016 HMI
SIPLACE Mat. Tower Storage Service Manual © ASM 3-3
If the refit of shelves and items does not meet the original positions, the machine crashes
and can be damaged.
Unplug ribbon cables
Unplug both ribbon cables (see picture).
Loosen and remove fixing screws
Loosen and remove the four fixing screws.