00197973-10_SM_MaterialTower.pdf - 第52页

X Axis 0019797 3 - 10 / 02 , 2016 4- 12 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al 4.2.4 Exchange steps Step 1 Loose n the rigid couplin g by loosenin g the screw. Step 2 Loosen the five scre ws that are reta in…

100%1 / 274
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-11
Time needed
Schedule around 20 to 30 minutes for this task.
4.2.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
All stored items must be unloaded in advance.
Machine operating
condition:
Shut down
Main electrical
power:
Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
Equipment disconnected from compressed air or nitrogen supply.
Access:
Open both doors of the machine.
X Axis 00197973-10 / 02 , 2016
4-12 © ASM SIPLACE Mat. Tower Storage Service Manual
4.2.4 Exchange steps
Step 1
Loosen the rigid coupling by loosening the
screw.
Step 2
Loosen the five screws that are retaining the belt
tensioner.
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-13
Step 3
Loosen the tension of the belt by turning the nut
of the belt tensioner.
Step 4
The belt is now loose and can be exchanged.