00197973-10_SM_MaterialTower.pdf - 第52页
X Axis 0019797 3 - 10 / 02 , 2016 4- 12 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al 4.2.4 Exchange steps Step 1 Loose n the rigid couplin g by loosenin g the screw. Step 2 Loosen the five scre ws that are reta in…

00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-11
Time needed
Schedule around 20 to 30 minutes for this task.
4.2.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
•
All stored items must be unloaded in advance.
Machine operating
condition:
• Shut down
Main electrical
power:
• Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.
Access:
• Open both doors of the machine.

X Axis 00197973-10 / 02 , 2016
4-12 © ASM SIPLACE Mat. Tower Storage Service Manual
4.2.4 Exchange steps
Step 1
Loosen the rigid coupling by loosening the
screw.
Step 2
Loosen the five screws that are retaining the belt
tensioner.

00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-13
Step 3
Loosen the tension of the belt by turning the nut
of the belt tensioner.
Step 4
The belt is now loose and can be exchanged.