00197973-10_SM_MaterialTower.pdf - 第59页

0019797 3 - 10 / 02 , 2016 X Axis SIPLACE Mat. Towe r St ora ge Serv ice Manual © ASM 4- 19 4.3 Hybrid cable X drag chain 4.3.1 Introducti on This modification instructi on describes how t o change the hy brid cable X dr…

100%1 / 274
X Axis 00197973-10 / 02 , 2016
4-18 © ASM SIPLACE Mat. Tower Storage Service Manual
Step 8
Use Loctite on all screws.
Fasten the screw of the coupling using a torque
key adjusted on 2.5 Newton.
Step 9
Remove all tools and close the doors of the machine.
Plug in the power connector and switch on the machine.
Initialize the machine by means of the software.
Step 10
In the software, in
System - Storage
Devices/Units
select the appropriate machine in
the table and press
Load.
In tab
Calibration calibrate the X axis and follow
the instructions given by the so
ftware.
00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-19
4.3 Hybrid cable X drag chain
4.3.1 Introduction
This modification instruction describes how to change the hybrid cable X drag chain on SIPLACE
Material Tower.
Spare part number: 03124542-01
Before starting the maintenance, read the Safety instructions carefully.
4.3.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key nr. 3 and 5
Screwdriver 00
Side cutter
Auxiliary Material: Cable ties
Sticky tape or labels
Pen
Spare parts:
03124542
-01 Hybrid Cable
Time needed
Schedule around 1 to 1.5 hours for this task.
X Axis 00197973-10 / 02 , 2016
4-20 © ASM SIPLACE Mat. Tower Storage Service Manual
4.3.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
Stored items do not have to be unloaded.
Machine operating
condition:
Shut down
Main electrical
power:
Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
Equipment disconnected from compressed air or nitrogen supply.
Access:
Open both doors of the machine.
4.3.4 Exchange steps
Prepare working space
Move the axes manually to the position shown
on picture (to the right of the machine) to have
easy access to the needed working space.