0019797 3 - 10 / 02 , 2016 Serv ice D oor M onit oring SIPLACE Mat. Tower St ora ge Ser vice Manu a l © ASM 12 -5 Preparation of sens ors Fix both se nsors and both magnets to the suppor t plates, shown o n t he pi cture…

100%1 / 274
Service Door Monitoring 00197973-10 / 02 , 2016
12-4 © ASM SIPLACE Mat. Tower Storage Service Manual
12.1.4 Mounting steps
Mechanical preparation
Note:
During the drilling works, take care no
metal chips can get into the machine.
Possibly use the vacuum cleaner to suck
away the metal chips.
On top of each door, two holes have to be drilled
to fix the safety switches and magnets (a total of
8 holes). See
the pictures for the positions of the
holes and mark it using a pencil. Alternatively
cut out the printed drilling jig on the last page of
the door monitoring description, follow the
direction to fold it.
Take a center punch and punch each marked
hole po
sition or punch through the drilling jig.
By means of the power drill and a drill with a
diameter of 3 mm all holes can be drilled.
Countersink all holes from the outer surface so
that the screws are flush with the door surface.
Countersink also the hol
es from the inner
surface for burr removing.
00197973-10 / 02 , 2016 Service Door Monitoring
SIPLACE Mat. Tower Storage Service Manual © ASM 12-5
Preparation of sensors
Fix both sensors and both magnets to the
support plates, shown on the picture.
The sensor fixation has slotted
holes for
adjusting the sensor. For the preparation the
sensor should be flush with the edge of the
support plate (1).
Preparation for cabling
On both sides of the machine, the sensor switch
(the part with the cable) is mounted on the door
with the locking mechanism (1), see picture.
On the left and the right side of the machine, the
hole (1) of the reinforcing bracket (diameter 15
mm) will be used as cable bushing (at the doors
with locking mechanism). To protect the cable a
grommet has to be mounted.
Mount the grommets on the holes on both sides
of the machine (see picture).
Service Door Monitoring 00197973-10 / 02 , 2016
12-6 © ASM SIPLACE Mat. Tower Storage Service Manual
On the right side of the machine, mount an edge
protector on top between reinforcing bracket
and stack (see picture series). It is the aim to
protect the sensor cable. The blank edge of the
sheet metal would scrub
at the cable as a result
of door opening and closing and possible
vibrations.
Grasp the edge protector by means of a long
-
nose plier.
Slide the edge protector over the edge of the
sheet metal.
At the end, press the edge protector down by
using a screw
driver.
On the left side of the machine, if not already
exist, mount an edge protector on the side of
the sheet metal where the existing cables are.
Scrubbing on the left side is not that critical, but
to prevent any malfunction it is recommended
to mount
the protector.