00197973-10_SM_MaterialTower.pdf - 第60页
X Axis 0019797 3 - 10 / 02 , 2016 4- 20 © ASM SIPLACE Mat. Tower St ora ge Ser vice Manu al 4.3.3 Prere quisites For a safe an d efficient maintena nce, the following pr erequisites have t o be fulfilled: Personnel: • An…

00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-19
4.3 Hybrid cable X drag chain
4.3.1 Introduction
This modification instruction describes how to change the hybrid cable X drag chain on SIPLACE
Material Tower.
Spare part number: 03124542-01
Before starting the maintenance, read the Safety instructions carefully.
4.3.2 Tools, Material and Scheduling
For an effective and efficient maintenance, the following resources have to be provided:
Required Tools / Auxiliary Material / Spare parts
Tools: Allen key nr. 3 and 5
Screwdriver 00
Side cutter
Auxiliary Material: Cable ties
Sticky tape or labels
Pen
Spare parts:
03124542
-01 Hybrid Cable
Time needed
Schedule around 1 to 1.5 hours for this task.

X Axis 00197973-10 / 02 , 2016
4-20 © ASM SIPLACE Mat. Tower Storage Service Manual
4.3.3 Prerequisites
For a safe and efficient maintenance, the following prerequisites have to be fulfilled:
Personnel:
• Any work with or at the equipment must be carried out by skilled and
trained personnel in accordance with the locally applicable
regulations.
• Inform all involved persons regarding the currently running
maintenance works.
Machine loading:
• Stored items do not have to be unloaded.
Machine operating
condition:
• Shut down
Main electrical
power:
• Equipment disconnected from power supply system. The Main Switch
(switched off) locked by means of a padlock to secure the main switch
against unintentional switching on.
Compressed air /
Nitrogen (if used):
• Equipment disconnected from compressed air or nitrogen supply.
Access:
• Open both doors of the machine.
4.3.4 Exchange steps
Prepare working space
Move the axes manually to the position shown
on picture (to the right of the machine) to have
easy access to the needed working space.

00197973-10 / 02 , 2016 X Axis
SIPLACE Mat. Tower Storage Service Manual © ASM 4-21
The hybrid cable X, marked on picture, will be
exchanged.
Remove hybrid cable from motor
Cut off and remove all cable ties.
Pull out the plugs (1) + (2).
Loosen and remove the two screws of the cable
shields (3).
Exchange hybrid cable
Loosen and remove the two screws of the cable
clamping.
Remove the defective hybrid cable.
Place the new hybrid cable int
o position.
Mount all the clamping parts as they were
before.
Screw in the clamping screws but do not tighten
them.