00196504-02_UM_X-Serie_SR70X_EN.pdf - 第177页

User manual SIPLACE X-series Technical data for the machine From software version SR.70x.xx 01/2011 EN edition X feeder modules 177 3.9.2.4 16 mm X t ape feeder module 3 Fig. 3.9 - 6 16 mm X tape feeder module 3 16 mm X …

100%1 / 448
Technical data for the machine User manual SIPLACE X-series
X feeder modules From software version SR.70x.xx 01/2011 EN edition
176
3.9.2.3 12 mm X tape feeder module
3
Fig. 3.9 - 5 12 mm X tape feeder module
3
3
3
3
3
12 mm X tape feeder module item no. 00141271-xx
12 mm X tape feeder module with splice sensor item no. 00141291-xx
Width 22.6 mm
Feeder module locations filled 2
Conveyor increment from 4 mm to 16 mm in 4 mm increments
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
8 s
User manual SIPLACE X-series Technical data for the machine
From software version SR.70x.xx 01/2011 EN edition X feeder modules
177
3.9.2.4 16 mm X tape feeder module
3
Fig. 3.9 - 6 16 mm X tape feeder module
3
16 mm X tape feeder module item no. 00141272-xx
16 mm X tape feeder module with splice sensor item no. 00141292-xx
Width 34.4 mm
Feeder module locations filled 3
Conveyor increment from 4 mm to 20 mm in 4 mm increments
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
8 s
Technical data for the machine User manual SIPLACE X-series
X feeder modules From software version SR.70x.xx 01/2011 EN edition
178
3.9.2.5 24 mm X tape feeder module
3
Fig. 3.9 - 7 24 mm X tape feeder module
3
3
3
24 mm X tape feeder module item no. 00141273-xx
24 mm X tape feeder module with splice sensor item no. 00141293-xx
Width 34.4 mm
Feeder module locations filled 3
Conveyor increment from 4 mm to 32 mm in 4 mm increments
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
8 s