00196504-02_UM_X-Serie_SR70X_EN.pdf - 第378页
Station extensions User manual SIPLACE X-series Nozzle changer From softwar e version SR.70x.xx 01/2011 EN edition 378 6.1.3.5 Position of the nozzle changers for t he T winSt ar on the X2 machine A nozzle changer ma y b…

User manual SIPLACE X-series Station extensions
From software version SR.70x.xx 01/2011 EN edition Nozzle changer
377
6.1.3.4 Position of the nozzle changers for the TwinStar on the X3 machine
A nozzle changer may be installed for each TwinStar at the following locations:
Nozzle changer 1 at location 3 (item 1 in Fig. 6.1 - 23
): 12 magazines
Nozzle changer 2 at locations 2 and 4 (item 5 in Fig. 6.1 - 23
): 10 magazines each
This gives a total capacity of 3 nozzle changers with 32 magazines and a total of 64 nozzle hold-
ers.
6
Fig. 6.1 - 23 Position of the nozzle changers for the TwinStar on the X3 machine
(1) Nozzle changer 1 (TH)
(2) Standard magazine
(3) Magazine for special nozzles or grippers
(4) Component reject bin
(5) Nozzle changer 2 (TH)
PLEASE NOTE 6
If there is an MTC installed at location 4, then the "Nozzle changer for the TwinStar in the place-
ment area with 2 gantries and docked MTC" option must be set up there (see Section 6.1.3.7,
from page 380).

Station extensions User manual SIPLACE X-series
Nozzle changer From software version SR.70x.xx 01/2011 EN edition
378
6.1.3.5 Position of the nozzle changers for the TwinStar on the X2 machine
A nozzle changer may be installed for the TwinStar at locations 1 to 4.
Nozzle changer 1 at locations 1 and 3 (item 1 in Fig. 6.1 - 24
): 12 magazines each
Nozzle changer 2 at locations 2 and 4 (item 5 in Fig. 6.1 - 24
): 10 magazines each
This gives a total capacity of 4 nozzle changers with 44 magazines and a total of 88 nozzle hold-
ers.
6
Fig. 6.1 - 24 Position of the nozzle changers for the TwinStar on the X2 machine
(1) Nozzle changer 1 (TH)
(2) Standard magazine
(3) Magazine for special nozzles or grippers
(4) Component reject bin
(5) Nozzle changer 2 (TH)
PLEASE NOTE 6
No nozzle changer can be set up at location 4 if there is an MTC installed there.

User manual SIPLACE X-series Station extensions
From software version SR.70x.xx 01/2011 EN edition Nozzle changer
379
6.1.3.6 Assembly
The nozzle changer is fixed to the component trolley docking unit.
6
Fig. 6.1 - 25 Assembly position
(1) Marking hole
(2) Operator side
(3) Arrow pointing toward the PCB conveyor
6
→ Align the nozzle changer so that the marking hole (item 1) is on the left, as viewed by the op-
erator.
WARNING 6
Only install the associated nozzle changer for each placement head. There is a risk of head
crashes with mixed configurations.