Setting up and commissioning User manual SIPLACE X-series Setting up the machine From software version SR.70x.xx 01/2011 EN edition 240 → Release the two hor izontal tensio ners (item 6 in Fig. 4.3 - 8 , p age 239 ). CAU…

User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Setting up the machine
239
4.3.7.2 Assembly
4
Fig. 4.3 - 8 Fitting the extension kit on the PCB output side
(1) Extension kit
(2) Door
(3) Fillister head screw DIN 912, M6x16 and washer
(4) Ground connection point
(5) Conveyor cover
(6) Side panel, detached
(7) Drawer unit rail
(8) Axis unit, gantries 1 and 3 (X2), axis unit, gantry 3 (X3) or axis unit, gantries 2 and 3 (X4)

Setting up and commissioning User manual SIPLACE X-series
Setting up the machine From software version SR.70x.xx 01/2011 EN edition
240
→ Release the two horizontal tensioners (item 6 in Fig. 4.3 - 8, page 239).
CAUTION 4
Do not unscrew the three bottom screws straight away. Simply loosen them so that the side
plate does not fall off.
→ Detach the ground cable from the side plate.
→ Remove both doors (item 2 in Fig. 4.3 - 8
, page 239) from the extension kit (item 1).
PLEASE NOTE: 4
To avoid damage, we recommend that a second person helps to assemble the extension kit.
→ Set down the axis unit (item 8 in Fig. 4.3 - 8
, page 239) at the side of the machine in order to
make enough space to fit the extension kit (item 1 in Fig. 4.3 - 8
, page 239).
→ Make sure that the connecting cables to the axis unit are not too tight.
→ Lift the extension kit (item 1 in Fig. 4.3 - 8
, page 239) against the machine frame and position
it so that the assembly bracket lies on the assembly bar (item 7 in Fig. 4.3 - 8
, page 239).
CAUTION 4
Make sure that the extension kit does not collide with the hexagonal shaft of the PCB con-
veyor and the hexagonal shaft becomes bent.
→ Fix the extension kit using 4 fillister head screws M6x16 and the associated washers (item 3
in Fig. 4.3 - 8
, page 239).

User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Setting up the machine
241
4.3.7.3 Fitting the guide for the hexagonal shaft
→ On the single conveyor, fix one guide for the hexagonal shaft (item 8 in Fig. 4.3 - 7, page 237)
to the extension kit using two fillister head screws M6x16 and washers.
→ On the double conveyor, fix two guides for the hexagonal shaft (item 8 in Fig. 4.3 - 7
, page
237
) to the extension kit using two fillister head screws M6x16 and washers.
4.3.7.4 Producing cable connections - extension kit on the PCB output side
4
4
4
4
4
Left-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
EMERGENCY STOP button
Start/stop button
X63/03020687 X63/03002526
Protective cover switch, location 3
X53/03020409 X53/03002528
Button for the component trolley docking unit,
location 3
X232/03021056 X232/03021053
Right-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Start/stop button
Switch, PCB conveyor cover
X62/03020410 X62/03002525
Protective cover switch, location 2
X52/03006476 X52/03002527
Button for the component trolley docking unit,
location 2
X222/03021056 X222/03021052