00196504-02_UM_X-Serie_SR70X_EN.pdf - 第330页

Tasks on the machine User manual SIPLACE X-series Setting up the feeder modules From software version SR.70x.xx 01/2011 EN edition 330 5.10.3.2 Inserting the X feeder module into the component t able 5 Fig. 5.10 - 3 Inse…

100%1 / 448
User manual SIPLACE X-series Tasks on the machine
From software version SR.70x.xx 01/2011 EN edition Setting up the feeder modules
329
Close the pick-up window (item 3 in Fig. 5.10 - 2) by returning the lever (item 4 in Fig.
5.10 - 2
) to its original position.
Remove loose components from the component table with a brush or use a vacuum
cleaner with appropriate nozzle.
PLEASE NOTE 5
If the component tape is already inserted, cut it off flush with the front edge of the feeder mod-
ule.
If the removal handle (item 1) is still protruding, then latch it in place.
5
Fig. 5.10 - 2 Check the X feeder module before using it
(1) Removal handle
(2) Cover foil rocker
(3) Pick-up window
(4) Lever for raising and latching the pick-up window
(5) Component disposal compartment
Tasks on the machine User manual SIPLACE X-series
Setting up the feeder modules From software version SR.70x.xx 01/2011 EN edition
330
5.10.3.2 Inserting the X feeder module into the component table
5
Fig. 5.10 - 3 Inserting the X feeder module into the component table
(1) Front slider guide for the X feeder module
(2) Back slider guide for the X feeder module
(3) "Back" centering pin on the X feeder module
(4) "Front" centering pin on the X feeder module
(5) Recesses in the centering bar for holding the "back" centering pin
(6) Centering holes on the component table for holding the "front" centering pin
(7) Locking latches
(8) Guide profile for the component table ( profile)
(9) Insertion aid for the feeder module
5
Place the front slider guide (item 1 in Fig. 5.10 - 3) of the feeder module on the insertion aid
(item 9 in Fig. 5.10 - 3
) of the component table.
Hold the feeder module vertically and push it forward, along the guide profile (item 8 in Fig.
5.10 - 3
). The front (item 1 in Fig. 5.10 - 3) and rear (item 2 in Fig. 5.10 - 3) slider guides of
the feeder module slide on the guide profile (item 8 in Fig. 5.10 - 3
).
User manual SIPLACE X-series Tasks on the machine
From software version SR.70x.xx 01/2011 EN edition Setting up the feeder modules
331
Carefully push the feeder module further until the "front" centering pin (item 4 in Fig. 5.10 - 3,
page 330
) is pushed into the centering hole (item 6 in Fig. 5.10 - 3, page 330).
Check the "back" centering pin (item 3 in Fig. 5.10 - 3
, page 330) of the feeder module as you
do so. This must slide easily into the recess (item 5) in the centering bar, otherwise the feeder
module is not seated vertically on the component table or it was not placed on the guide pro-
file (item 8 in Fig. 5.10 - 3
, page 330) correctly.
When the feeder module is at the stop position, the locking latch (item 7 in Fig. 5.10 - 3
, page
330
) latches on the locking roller of the feeder module (item 1 in Fig. 3.9 - 1, page 172). If you
have forgotten to engage the removal handle (item 1 in Fig. 5.10 - 2
, page 329), the status
display on the feeder module's operator panel will light up red after a few seconds. The LCD
display contains the error message "Handle --->>" (see Fig. 5.11 - 1
, page 337).
Engage the removal handle (item 1 in Fig. 5.10 - 2
, page 329). The feeder module's sta-
tus display now lights up green and the feeder module is on standby. The track number
and conveyor increment can be read on the LCD display once more.
5.10.4 Placing component tape on the X feeder module
5.10.4.1 Checking the X tape feeder module
When you place the component tape in the feeder module, first check whether there are
any components in the vicinity of the pick-up window (item 2 in Fig. 5.10 - 5
, page 333).
Remove any components that you find since they could cause a fault.
5.10.4.2 Preparing the component tape for insertion
Check that there is a straight cut edge at the start of the component tape.
If the transport holes are torn or bent, cut off this part of the tape.
Also make sure that there are no streaks of adhesive on the cover foil.
Pull around 30 cm cover foil away from the component tape if this does not expose any
components.
PLEASE NOTE 5
Use an SMD tape threader if there is insufficient cover foil available to make sure that no com-
ponents are lost:
for the 8 mm component tape:item no. 00355265-xx
for the 12 mm component tape:item no. 00356342-xx
Shorten the component tape with the now exposed component pockets by around 3 cm.