00196504-02_UM_X-Serie_SR70X_EN.pdf - 第73页
User manual SIPLACE X-series Operational safety From software version SR.70x.xx 01/2011 EN edition Safety equipment 73 two cover flap s (item 3 and 4) over the input or o utput belt of the PCB conveyor prevent access to …

Operational safety User manual SIPLACE X-series
Safety equipment From software version SR.70x.xx 01/2011 EN edition
72
2.6 Safety equipment
2.6.1 Protective covers
2
Fig. 2.6 - 1 Protective covers
(1) Protective cover, short
(2) Protective cover, long
(3) Cover flap and hand guard on the input belt
(4) Cover flap and hand guard on the output belt
2
The traveling range of the gantries has two protective covers that can be swung upwards (items
1 and 2). There are side screens to prevent access to the inside of the machine from the side. The

User manual SIPLACE X-series Operational safety
From software version SR.70x.xx 01/2011 EN edition Safety equipment
73
two cover flaps (item 3 and 4) over the input or output belt of the PCB conveyor prevent access
to the PCB conveyor.
Function 2
The main power supply to the gantry axes is interrupted immediately if one of the protective covers
is swiveled up or one of the cover flaps on the PCB conveyor is raised. The gantry axes stop mov-
ing. The message "Close cover" is displayed on the screen.
→ Close the protective covers and press one of the start buttons (Pos. 1 in Fig.
2.6 - 2
) to continue placement.
2
Fig. 2.6 - 2 Position of the start buttons (white) on the machine
(1) Start button (white) on the machine

Operational safety User manual SIPLACE X-series
Safety equipment From software version SR.70x.xx 01/2011 EN edition
74
2.6.2 Switches and buttons on the machine
2.6.2.1 Position of switches and buttons on the machine
2
Fig. 2.6 - 3 Position of switches and buttons - View of the PCB output side
(1) Main power switch
(2) Stop button (black) on the operator panel on the power supply side
(3) Start button (white) on the operator panel on the power supply side
(4) Component counter on the operator panel on the power supply side
(5) Emergency stop button on the output side
(6) Start button (white) on the output side
(7) Stop button (black) on the output side
(8) Button (black) for docking the component trolley in or out, location 2
(9) Button (black) for docking the component trolley in or out, location 3
(T) PCB transport direction