03217917-01-01E By DEK Technical Reference Manual Vol 1_enPDFA.pdf - 第217页

15 BOARD STOP 15.6 ADJUSTMENTS AND SETTINGS TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 217 ► Fit the base clamp locating nut (5) into the attachment slot (6) on the right hand side of the rising table. 5 6 ► Attac…

100%1 / 292
15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
216 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
Loosen the base clamp securing screw (4) sufficiently, using a 4mm Allen key, to remove the
base clamp (3) from the machine.
4
3
Remove the base clamp locating nut (5) from the attachment slot (6) on the left hand side of
the rising table.
5
6
15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 217
Fit the base clamp locating nut (5) into the attachment slot (6) on the right hand side of the
rising table.
5
6
Attach the base clamp (3) to the locating nut (1), in the correct position in the Y axis for the
product, using a 4mm Allen key and M5 securing screw and washer (4).
3
4
Mark the centre point, in the X axis, on the front of the product board.
Place the product board on the rails with the board centre point at the Camera Reference Po-
sition (white dot on front rail).
Before fitting the remote board stop assembly (2) to the base clamp (3), ensure that the board
stop is configured for right hand side operation, carry out 15.6.2.2 "RHS Configuration" [}201]
section of this chapter.
15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
218 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
Lay the remote board stop assembly onto the base clamp so that the board stop is clear of the
board.
1
3
2
Using the appropriate slots, loosely secure the remote board stop assembly (2) to the base
clamp (3), using the four M5 cap head screws (1).
Connect plug 8PL05 to socket 8SK05R.
Connect the pipe marked Remote/B/Stop R1 to the in-line connector on the pipe marked 1 on
the remote board stop.
Connect the pipe marked Remote/B/Stop R2 to the in-line connector on the pipe marked 2 on
the remote board stop.
Refit the right and left hand side safety covers.
Reconnect the mains air quick release connection to the machine.
Switch the mains isolator to ON.
Press the Start button.
When prompted select Diagnostics.
When prompted press the System button.
Carry out 15.6.3 "Setting the Remote Board Stop" [}203].