03217917-01-01E By DEK Technical Reference Manual Vol 1_enPDFA.pdf - 第29页

3 SAFETY FEATURES 3.2 GENERAL TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 29 3.2.2 Opening Covers Opening printhead covers are fitted with a cam interlock switch to protect personnel from internal moving parts. 3.2…

100%1 / 292
3 SAFETY FEATURES
3.2 GENERAL
28 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
3.2.1 Emergency Stop (E Stop)
The machine is fitted with an E Stop which suspends all machine operations. The switch is within
easy reach of the operator and once pressed, the latching switch requires resetting.
To reset the E Stop, turn the button clockwise until it unlatches.
Pressing the E Stop or opening the printhead cover cuts the servo axes power supply. A warning of
this condition is reported on the machine monitor.
3.2.1.1 E Stop Module Shut Down
If the E Stop loop is opened by pressing the E Stop or opening the printhead cover, an emergency
stop is initiated via the E Stop module. When actuated the following areas of the machine are
rendered inactive:
Lid Bolt
Moving Rail Stepper
Print Carriage Servo (axis stopped before power is removed)
Rail System Front and Rear Belt Motor Drives
Rising Table Brake (brake engages when power is cut)
Rising Table Servo
Squeegee Stepper Motor(s)
System Lamp
Understencil Cleaner Paper Feed Motor
Understencil Cleaner Solvent Pump
Understencil Cleaner Squeegee Solenoid
Vacuum Tooling Solenoid
X Camera Motor (axis stopped before power is removed)
X Forward, X Rear and Y Chase Alignment Stepper Motors
Y Camera Motor (axis stopped before power is removed)
3.2.1.2 Recovery
When normal working conditions are restored, release the E Stop switch and, when prompted by a
screen message, press the System button.
3 SAFETY FEATURES
3.2 GENERAL
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 29
3.2.2 Opening Covers
Opening printhead covers are fitted with a cam interlock switch to protect personnel from internal
moving parts.
3.2.2.1 Lid Bolt
Lid bolts are fitted to all opening printhead covers to prevent them from being raised during the
print cycle.
The lid bolts are withdrawn and the printhead cover may be raised when:
Open Cover is requested by software
Pause or stop is selected during a print cycle
The E Stop is pressed
3.2.3 Jog Buttons
The two button control switches or jog buttons are positioned such as to maintain maximum safety
for the operator whilst solvent priming or paper feeding with the printhead cover open. This requires
both buttons to be depressed simultaneously for the function to become active. The use of these
buttons is dependent on the function selected on the machine monitor. During normal operation
these buttons control paper feed and solvent prime operations. When in maintenance mode, the
two button control switches control the movement of the following diagnostics:
Print Carriage
Squeegee Assembly
Camera Axes
Rail System
Screen Alignment
Rising Table
Only one button is required to drive the selected mechanism, the two buttons are used to drive the
mechanism in opposite directions, ie jog forward or jog back.
3 SAFETY FEATURES
3.3 PRINTHEAD COVER
30 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
3.3 PRINTHEAD COVER
3.3.1 Safety Interlocks
The safely features designed into the printer are for the protection of all operators and maintenance
personnel. ASM strongly recommended safety devices are never overridden.
Opening the printhead cover allows access to the following areas:
Printhead
Squeegee
Stencil
Under Stencil Cleaner
Tooling
The printhead cover is accessible to the operator and an interlock safety switch protects personnel
from the mechanisms during normal line operations. Lifting the cover cuts power to all motors and
selected actuators, via the E Stop module, to all printer modules,
Pneumatically operated lid bolt(s) prevent the cover being raised during the print cycle. The lid bolt
is withdrawn and the cover may be raised:
When Open Cover is requested by software
When pause or stop is selected during a print cycle
When the E Stop is pressed
3.3.2 Recovery
When the printhead cover is closed, normal working condition is restored and the line may be re-
started. Pressing the system button enables resumption of operations, where this is allowed by the
control system.