16 TRANSPORT RAILS MODULE 16.4 ADJUSTMENTS AND SETTINGS TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 235 16.4.2 Board at Left/Right Optos The board at left/right optos switching threshold can be adjusted by means of…

100%1 / 292
16 TRANSPORT RAILS MODULE
16.4 ADJUSTMENTS AND SETTINGS
234 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
Select Rails To Board Width.
Adjust the sensor position, so that a 3.5mm gauge fits between the sensor and the top face of
the clatter bar and a 4mm gauge does not fit, at the rear right rail transport leg. Repeat for left
hand end of the rail.
Select Back.
Select Exit Diagnostics.
Select Confirm.
16 TRANSPORT RAILS MODULE
16.4 ADJUSTMENTS AND SETTINGS
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 235
16.4.2 Board at Left/Right Optos
The board at left/right optos switching threshold can be adjusted by means of a sensitivity control.
This ensures that when a board is fed into the machine (via the transport belts) the sensor output
switches to ON.
To achieve an optimum setting carry out the following procedure:
Place a board on the rails covering the sensor.
Turn the sensitivity control (1) fully anti-clockwise, ensure that the amber LED (2) is OFF.
+
-
1
2
Re-adjust the sensitivity control (1) clockwise until the amber LED (2) is ON.
NOTE
If the amber LED is flashing, this indicates a week signal. Re-adjust the sensitivity control.
Remove the board from the rails and confirm the amber LED is OFF.
Turn the board 90° and position back onto the rail system, (so that the board lies on top of the
rail system as shown in the figure below).
16 TRANSPORT RAILS MODULE
16.4 ADJUSTMENTS AND SETTINGS
236 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
Confirm that the amber LED is OFF. If the amber LED is ON, turn the sensitivity control anti-
clockwise until the amber LED is OFF.
Remove the board.
Position the board back on the rail system, as in Step 1, and confirm that the amber LED is
ON.
If the board has holes or cut-outs, go to continue at next Step. If the board has no holes or
cut-outs remove the board from the rails and confirm that the amber LED is OFF.
Slide the board backward and forward across the sensor ensuring that the LED is only
triggered by the leading and trailing edges of the board.
If the LED flickers when encountering holes or cut-outs, turn the sensitivity control clockwise a
further quarter turn.
Repeat previous two Steps until the correct setting is achieved.
Remove the board from the rails and confirm that the amber LED is OFF.