CP40 service manual.pdf - 第13页

Contents Chapter Title Version Date WA QA CA Remarks 12 Performance/Efficiency 00 Nov.04 O O O 12-1 Fault Diagnosis Guide Table O O O 12-2 Fault Diagnosis O O O 12-3-1 Part Pick Up Error O O O 12-3-2 Compliance Ass'…

100%1 / 250
Contents
Chapter Title Version Date WA QA CA Remarks
11 Utility Part 00 Nov.04 O O O
11-1 Fault Diagnosis Guide Table O O O
11-2 Fault Diagnosis O O O
11-3-1 Utility Specification O O O
11-3-2 Input Voltage Check O O O
11-3-3 Air Ass'y O O O
11-3-4 Specified Pressure Check O O O
11-3-5 Air Filter & Auto Drainer O O O
11-3-6 CP-40 SPEC O O O
11-3-6-1 Differences from CP-40L/LV O O O
11-3-6-2 SPEC Verification O O O
11-3-7 CP-40 Grease Specification O O O
Contents
Chapter Title Version Date WA QA CA Remarks
12 Performance/Efficiency 00 Nov.04 O O O
12-1 Fault Diagnosis Guide Table O O O
12-2 Fault Diagnosis O O O
12-3-1 Part Pick Up Error O O O
12-3-2 Compliance Ass'y Check O O O
12-3-3 Part Bounce or Place Error O O O
12-3-4 Tray Feeder Pick Up Error O O O
12-3-5 IC Vision Check Error O O O
12-3-6 50M Head3 Setting O O O
50M
12-3-7 Aligner Offset Setting Method O O O
12-3-8 Auto MOUNTING INFORMATION O O O
12-3-9
CP40 Series Integrated Software Setup
Procedures
O O O
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
EMG(Emergency) $0001 Emergency switch is pressed. Release EMG(Emergency) Switch pressed.
$0021
Front door is opened
Error occurred when trying to operate system when front door is open.
$0022
Rear door is opened
Error occurred when trying to operate system when rear door is open.
$0040
Ready switch is off
Error occurred when trying to operate motor or execute program with <Ready>
switch not pressed.
Operate the system after applying power to a motor by pressing a <Ready> switch.
$0070
Can't make homing while FREEZE state
Error occurred when trying to find out Home Position by pressing <Home> key of
teaching box or at MMI.
Be sure to find out Home Position of motor only after releasing the error condition(FREEZE State) by
pressing <Reset> switch.
$0080
Can't accept MMI command while PAUSE or RUN. This does not effect on operation or performance of system. Additional corrective actions are not
required..
X-Y Axis Part $0100
Invalid nozzle length
Invalid nozzle length value among Nozzle data.(0 value is inputted.)
Check Nozzle Data with command of <System Setup/Standard Data/Standard Nozzle> in MMI and
then input the correct data.
4-3-4
$1100
Positive(+) H/W Limit is detected at the Warmup
Driving part of associated motor is detected by sensor located at positive(+)
direction during warming up.
$1110
Positive(+) H/W Limit is detected (X axis)
Driving part of associated motor is detected by sensor located at positive(+)
direction.
$1120
Positive(+) H/W Limit is detected (Y axis)
Driving part of associated motor is detected by sensor located at positive(+)
direction.
1-3-1
$1200
Negative(-) H/W Limit is detected at the Warmup
Driving part of associated motor is detected by sensor located at negative(-)
direction during Warming up.
$1210
Negative(-) H/W Limit is detected (X axis)
Driving part of associated motor is detected by sensor located at negative(-)
direction.
$1220
Negative(-) H/W Limit is detected (Y axis)
Driving part of associated motor is detected by sensor located at negative(-)
direction.
$1310
X Axis (+) S/W Limit is detected
Driving part of X-axis motor is reached to software limit of positive(+) direction
selected in system setup.
Close a front door of system and then operate it.
Find out Home Position of motor associated with Jog Key.
CP-40 Trouble Shooting Guide - Defined Fault