CP40 service manual.pdf - 第52页
MODULE ERROR CODE Symptom and Cause ACTION Service Manual $402, 1, "[Tape Feeder] ", "Station=%d Feeder=%d " Feeder No. is incorrect. Feeder No. shall be 1~76(for Tray Feeder) or 1~52(Stick Feeder). 4…

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
PMT Error
Code Table
$223, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Width dX value of Fiducial Mark is incorrect.
Width dX of Fiducial Mark shall be 0.1~10mm.
$224, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Width dY value of Fiducial Mark is incorrect.
Width dY of Fiducial Mark shall be 0.1~10mm.
$225, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Fiducial Mark scan speed is incorrect.
Fiducial Mark Scan speed shall be 1~100mm/s.
$226, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Part(Feeder) is not defined.
Define Feeder Unit and Feeder No.
$228, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Same (X, Y) coordinates exist between steps on Step-Program of PCB Setup.
Step-Program load is possible even if error occurs. But, modify the same coordinates in Step-
Program of PCB Setup because placement error can be occurred when actual placement.
$300,
$301, 1, 4-3-4
$309, 1,
"[ANC] ", "ANC=%d Hole=%d "
ANC type is incorrect.
Select the suitable ANC type.
(At this time, you should know how this PCB File is prepared initially.)
4-3-4
$311, 1,
"[ANC] ", "ANC=%d Hole=%d "
ANC Connect No. is incorrect.
ANC Connect No. shall be 1~4.
System not supplied with Option shall be 1~2.
4-3-2
$312, 1,
"[ANC] ", "ANC=%d Hole=%d "
Feeder station No. is incorrect.
Feeder Station No. shall be 1~2.
$313, 1,
"[ANC] ", "ANC=%d Hole=%d "
Feeder No. is incorrect.
Feeder No. shall be 1~52. 4-3-5
$314, 1,
"[ANC] ", "ANC=%d Hole=%d "
Nozzle type can not be matched to ANC type.
Adjust the Nozzle type to ANC type. 4-3-4
$1300, 4-3-4
$1302, 0, 4-3-4
$1303, 0,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
Y value of Nozzle position is incorrect.
Nozzle position Y value shall be in system area.
$1305, 0,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
Z value of Nozzle position is incorrect.
Move a Camera to hole of ANC concerned in Dialog Box displayed after executing the command of
<Setup/ANC Setting> of MMI, move down Z-axis of head concerned to Pickup position with teaching
box and click the <Get. Z> button.
$1315, 0,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
ANC is required.
Select the suitable ANC. 4-3-4
$400,
$401, 1,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
X value of Nozzle position is incorrect.
Nozzle position X value shall be in system area.
"[Tape Feeder] ", "Station=%d Feeder=%d "
Feeder station No. is incorrect.
Feeder Station No. shall be 1(Front)~2(Rear).
"[ANC] ", "ANC=%d Hole=%d "
Nozzle type is incorrect.
Select the suitable Nozzle type.
- 39 -

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$402, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Feeder No. is incorrect.
Feeder No. shall be 1~76(for Tray Feeder) or 1~52(Stick Feeder). 4-3-5
$403, 1
"[Tape Feeder] ", "Station=%d Feeder=%d "
Feeder type is incorrect.
Use the suitable Feeder. 4-3-2
$406, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Z position is incorrect.
Z position shall be -10~15mm.
$407, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d "
R value of angle is incorrect.
Angle R value shall be degree of -360~+360.
$408, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Link station No. of Feeder is incorrect.
Link Station No. of Feeder shall be 1~2.
$409, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Link No. of Feeder is incorrect.
Link No. of Feeder shall be 1 ~ 52.
$410, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Linked to itselt or forming the loop is not allowable.
Link to other Feeder No.
$411, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Linked to other parts.
Link to Feeder using the same part.
$412, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Dump Box is incorrect.
Use the suitable Dump Box.
$1400,
$1404, 0,
$1405, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d Head=%d "
Y value is incorrect.
Y value shall be in system area.
PMT Error
Code Table
$500,
$501, 1,
$502, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick No. is incorrect.
Stick No. shall be 1~10.
$506, 0,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Pickup height Z of Stick is incorrect.
Z position shall be -10~15mm.
$507, 0,
"[Stick Feeder] ", "Unit=%d Stick=%d "
R value of angle is incorrect.
Angle R value shall be degree of -360~+360.
$508, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick Unit link No. is incorrect.
Stick Unit Link No. shall be 1~10.
X value shall be in system area.
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick Unit No. is incorrect.
Stick Unit No. shall be 1~10.
"[Tape Feeder] ", "Station=%d Feeder=%d Head=%d "
X value is incorrect.
- 40 -

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$509, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick link No. is incorrect.
Stick Link No. shall be 1~10.
$510, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Linked to itselt or forming the loop is not allowable.
Link to other Stick No.
$511, 0,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Linked to other parts.
Link to Stick using same part.
$512, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Dump Box is incorrect.
Use the suitable Dump Box.
$514, 0,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Z value of Stick Feeder Dump position is incorrect.
Z value of Dump Box shall be -10~15mm.
$1500,
$1504, 0,
$1505, 0,
"[Stick Feeder]", "Unit=%d Stick=%d Head=%d"
Y value of Stick Feeder Pickup position is incorrect.
Stick Feeder Pickup position Y value shall be in system area.
$1513, 0,
"[Stick Feeder]", "Unit=%d Stick=%d Head=%d"
Y value of Stick Feeder dump position is incorrect.
Dump position Y value shall be in system area.
$600,
$601, 1,
$602, 1,
"[Tray Feeder] ", "Unit=%d Tray=%d "
Tray No. is incorrect.
Tray No. shall be 1~20.
$604, 1,
"[Tray Feeder] ", "Unit=%d Tray=%d "
No. of Tray X is incorrect.
No. of Tray X usable shall be 1~99.
$605, 1,
"[Tray Feeder] ", "Unit=%d Tray=%d "
No. of Tray Y is incorrect.
No. of Tray Y usable shall be 1~99.
$606, 0,
"[Tray Feeder] ", "Unit=%d Tray=%d "
Tray X length is incorrect.
Tray X length shall be 10~800mm.
$607, 0,
"[Tray Feeder] ", "Unit=%d Tray=%d "
Tray Y length is incorrect.
Tray Y length 10~800mm.
$610, 0,
"[Tray Feeder] ", "Unit=%d Tray=%d "
Z value of Tray Pickup height is incorrect.
Z value shall be -10~15mm.
$611, 0,
"[Tray Feeder] ", "Unit=%d Tray=%d "
R value of Tray Pickup angle is incorrect.
Angle R value shall be degree of -360~+360.
"[Stick Feeder]", "Unit=%d Stick=%d Head=%d"
X value of Stick Feeder Pickup position is incorrect.
Stick Feeder Pickup position X value shall be in system area.
"[Tray Feeder] ", "Unit=%d Tray=%d "
Tray Unit is incorrect.
Tray Unit No. shall be 1~3.
- 41 -