CP40 service manual.pdf - 第199页
8. Fix Camera (CP-40) Version Date WA QA CA Note 00 Nov04 O O O If Fix Camera Calibration is Completed Aut omatically, Measured Data is Displayed. => If the Measured D ata Specifies SPEC, S elect OK. At this time, Sel…

8. Fix Camera
(CP-40)
(Display1)
(Display3)
(Display2)
(Display5)
(Display4)
Version Date WA QA CA Note
00 Nov04 O O O

8. Fix Camera
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
If Fix Camera Calibration is Completed Automatically, Measured Data is Displayed.
=> If the Measured Data Specifies SPEC, Select OK.
At this time, Select Head Offset of Head Offset Calibration and Perform Head Offset Calibration Simultaneously
(Display5).
If Selecting Head Offset and then Clicking Next Nine Times, Head Offset is Measured Automatically
.
=> HEAD OFFSET is X,Y SPEC : +-0.05.
<< FIX CAMERA CALIBRATION DATA by Specification >>
XYR
20mm UPWARD VISION 40+-1
um
/PIXEL 40.5+-1
um
/PIXEL +-0.15 DEGREE
35mm UPWARD VISION 70+-1
um
/PIXEL 71+-1
um
/PIXEL +-0.15 DEGREE
45mm UPWARD VISION 90+-1
um
/PIXEL 91+-1
um
/PIXEL +-0.15 DEGREE

8. Fix Camera
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
Verify the Center Position
of Fix Camera.
J2101976
Mark Pad
CheckitisFixedto
No.41 of Rear Feeder Base.
for Fixing Fex
Camera
If Calibration is Performed
over Tolerance, Loosen Four
Hexagon Wrench Bolts with
M2.5 T-Wrench.
8-3-3. Fix Camera Check Point