CP40 service manual.pdf - 第28页

MODULE ERROR CODE Symptom and Cause ACTION Service Manual $8271 Object size caliper error (Head 1) Fails to receive the object size measurement command caused by communication error. 7-3-1 $8272 Object size caliper error…

100%1 / 250
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$8111
Aligner Zero Count Reset Error (Head 1)
Pulse counter of aligner fails to be initialized to 0 after finding out Home position of θ
-axis.(Communication Error).
$8112
Aligner Zero Count Reset Error (Head 2)
Pulse counter of aligner fails to be initialized to 0 after finding out Home position of θ
-axis.(Communication Error).
1-3-1
7-3-1
$8113
Aligner Zero Count Reset Error (Head 3)
Pulse counter of aligner fails to be initialized to 0 after finding out Home position of θ
-axis.(Communication Error).
$8141
Data Load Error (Head 1)
Fails to transfer Theta offset command to Aligner DSP board.(Communication
error).
$8142
Data Load Error (Head 2)
Fails to transfer Theta offset command to Aligner DSP board.(Communication
error).
1-3-1
7-3-1
$8143
Data Load Error (Head 3)
Fails to transfer Theta offset command to Aligner DSP board.(Communication
error).
$8211
Data Load Error (Head 1)
Fails to transfer part to align to aligner DSP board.(Communication error).
Woori Align
Part
$8212
Data Load Error (Head 2)
Fails to transfer information on part to align to aligner DSP board.(Communication
error).
$8213
Data Load Error (Head 3)
Fails to transfer information on part to align to aligner DSP board.(Communication
error).
$8241
Align Start Error (Head 1)
Communication error occurs when executing Align.
$8242
Align Start Error (Head 2)
Communication error occurs when executing Align.
$8243
Align Start Error (Head 3)
Communication error occurs when executing Align.
$8251
Align result response error (Head 1)
Fails to receive the results of align caused by communication error.
1-3-2
$8252
Align result response error (Head 2)
Fails to receive the results of align caused by communication error.
1-3-3
$8253
Align result response error (Head 3)
Fails to receive the results of align caused by communication error.
1-3-6
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
- 14 -
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$8271
Object size caliper error (Head 1)
Fails to receive the object size measurement command caused by communication
error.
7-3-1
$8272
Object size caliper error (Head 2)
Fails to receive the object size measurement command caused by communication
error.
$8273
Object size caliper error (Head 3)
Fails to receive the object size measurement command caused by communication
error.
$8311
Nozzle find Error (Head 1)
Communication error occurs when Z-axis finds out Align height of Nozzle.
$8312
Nozzle find Error (Head 2)
Communication error occurs when Z-axis finds out Align height of Nozzle.
$8313
Nozzle find Error (Head 3)
Communication error occurs when Z-axis finds out Align height of Nozzle.
$8321
Nozzle Inspection Error (Head 1)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8322
Nozzle Inspection Error (Head 2)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8323
Nozzle Inspection Error (Head 3)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8331
Nozzle Inspection Result Error (Head 1)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8332
Nozzle Inspection Result Error (Head 2)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8333
Nozzle Inspection Result Error (Head 3)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8341
Nozzle Check Error. Please check Nozzle. (Head 1)
Occurs when nozzle exists actually in head however program indicates no nozzle
exists in the head.
4-3-2
$8342
Nozzle Check Error. Please check Nozzle. (Head 2)
Occurs when nozzle exists actually in head however program indicates no nozzle
exists in the head.
4-3-4
Woori Align
Part
$8343
Nozzle Check Error. Please check Nozzle. (Head 3)
Occurs when nozzle exists actually in head however program indicates no nozzle
exists in the head.
Check for abnormal conditions of Nozzle data in dialog box displayed after executing the command
of <Setup/ANC Setting> in MMI.
4-3-2
4-3-4
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
Check for abnormal conditions of Nozzle data in dialog box displayed after executing the command
of <Setup/ANC Setting> in MMI.
- 15 -
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$8351
Nozzle Run-out check error (Run-out>0.120mm) (Head 1)
Run-out of nozzle exceeds 0.12mm.
This has an effect on align check and installment accuracy.
$8352
Nozzle Run-out check error (Run-out>0.120mm) (Head 1)
Run-out of nozzle exceeds 0.12mm.
This has an effect on align check and installment accuracy.
12-3-2
$8353
Nozzle Run-out check error (Run-out>0.120mm) (Head 1)
Run-out of nozzle exceeds 0.12mm.
This has an effect on align check and installment accuracy.
$8701
Aligner result response Error (Head 1)
Fails to receive align results caused by communication error.
$8702
Aligner result response Error (Head 2)
Fails to receive align results caused by communication error.
1-3-1
$8703
Aligner result response Error (Head 3)
Fails to receive align results caused by communication error.
7-3-1
$8711
Aligner Score is too low (Head 1)
Fails to algin during retrying times.
(Either align score of X and Y is less than 80).
$8712
Aligner Score is too low (Head 2)
Fails to algin during retrying times.
(Either align score of X and Y is less than 80).
$8713
Aligner Score is too low (Head 3)
Fails to algin during retrying times.
(Either align score of X and Y is less than 80).
$8731
Aligner component auto inspection error (Head 1)
Fails to find out align information automatically.
12-3-1
$8732
Aligner component auto inspection error (Head 2)
Fails to find out align information automatically.
12-3-3
$8733
Aligner component auto inspection error (Head 3)
Fails to find out align information automatically.
$8741
Please check nozzle in the Head (Head 1)
Nozzle fails to be inserted securely into Head securely.
4-3-2
$8742
Please check nozzle in the Head (Head 2)
Nozzle fails to be inserted securely into Head securely.
4-3-4
Nozzle is to be inserted securely into a Head.
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
Try again by pressing the Start switch after removing the error condition by pressing the <Reset>
switch of operation panel.
Check that part concerned exists in feeder, and for pickup conditions of part.
Replace a Compliance of Head concerned. (Recommendations)
- 16 -