NO Symptom Possible Cause Error Code Action
Instructio
n
1
Transformer Malfunction
Input Voltage is Low. Connect Disconnected Cable. 5-3-1
2 Noise Tighten Main Power Connector Bolts. 5-3-1
3
Power Supply
24V is not Output. Connect Disconnected 24VG and 24VP. 5-3-2
4 Bad Stick Feeder 24V AC/DC Lining 5-3-2
5 Front AC Power Malfunction Disconnect Cable. 5-3-2
6 When Checking I/O, 24V is Down. Modify CV CN 37 Pin. 2-3-2
7
OP Panel
Reset SW Always Remains ON. Replace Reset SW. 5-3-3
8
Functions of OP Panel SWs are
Exchanged.
Modify Soldering. 5-3-3
9 Ready SW Color is not Correct. Replace Lamp.
10 Main Panel SW Malfunction Modify Wiring.
11
Circuit Protect
Stick Feeder Malfunction Check and Replace CR9. 5-3-2
12 Servo Driver Malfunction Check and Replace Circuit Protect. 5-3-2
13 PC Malfunction Check and Replace CP1. 5-3-2
14 Step Driver Malfunction Check and Replace CR2-1. 5-3-2
15
16
17
5-2. Trouble Diagnosis
5. Electric Device
(CP-40)
5-3-1. Trans Former Replacement and Input Voltage Check
1. Close Program and Shut Circuit Break Off.
2. Disconnect Main Power Cable from Equipment.
2. Main Power Cable
Disconnection
Version Date WA QA CA Note
00 Nov04 O O O
1. Circuit Break Off
5. Electric Device
(CP-40)
3. Using Cross Screwdriver, Loosen Four M5*8 Toras Bolts to Disconnect Cover.
Toras M5*8 4ea
Rear Side Cover
Version Date WA QA CA Note
00 Nov04 O O O