CP40 service manual.pdf - 第151页

4. Feeder Base & ANC (CP-40) 8)Flow PCB to Check Proper Operation of Each Sensor. 7)Extend Pneumatic Air Hose to Place Stopper(Replace Newly) -.Refer to Fig. 4. #The Second Hose form the Right Among Air Blocks is for…

100%1 / 250
4. Feeder Base & ANC
(CP-40)
Origins
Coordinate System
Front Left
PCB Origin
603.375
Conveyor Direction
CCW
XY:
121.570
mm
X
Y
<Fig. 2> PCB Origin Setting
6)Exchange Locations of Sensor Connectors on Conveyor I/F Board.
CN29(IN SENSOR)
CN30(WAIT SENSOR)
CN31(PLACE SENSOR)
CN32(OUT SENSOR)
Conveyor I/F Board
Version Date WA QA CA Note
00 Nov04 O O O
4. Feeder Base & ANC
(CP-40)
8)Flow PCB to Check Proper Operation of Each Sensor.
7)Extend Pneumatic Air Hose to Place Stopper(Replace Newly) -.Refer to Fig. 4.
#The Second Hose form the Right Among Air Blocks is for Place Stopper.
<Fig. 4> Place Stopper Pneumatic Line
AIR HOSE
AIR BLOCK
Version Date WA QA CA Note
00 Nov04 O O O
5. Electric Device
(CP-40)
5-1. Trouble Diagnosis Guide Table
Malfunction
Trans Former Power Supply Op Panel Circuit Protect
CP Replacement 4
Power Supply Replacement 5
OP Panel SW Replacement 4
OP Panel SW Soldering Check 3
Lamp Replacement 3 5
Power Supply Cable Check
2
\
5
AC/DC Line Check 3 2 2 4
Cable Disconnection Check 4 1 3
Power Supply 24V Output Check 1
Main Power Input/output Check 1 1
Circuit Break Check 2
Parts
Symptom
Check and Action
# Number Indicates Priority of Check Items.