CP40 service manual.pdf - 第156页
5. Electric Device (CP-40) 4. Using Cross-head Stubby Screwdriver, Loosen Four M4*10 S pherical Head Bolts to Disconnect Acrylic Protection Cover from Main Transformer. => Loosen Four Hexagon Wrench Bolts to Disconnec…

5. Electric Device
(CP-40)
3. Using Cross Screwdriver, Loosen Four M5*8 Toras Bolts to Disconnect Cover.
Toras M5*8 4ea
Rear Side Cover
Version Date WA QA CA Note
00 Nov04 O O O

5. Electric Device
(CP-40)
4. Using Cross-head Stubby Screwdriver, Loosen Four M4*10 Spherical Head Bolts to Disconnect Acrylic Protection
Cover from Main Transformer.
=> Loosen Four Hexagon Wrench Bolts
to Disconnect Transformer from Body.
=> Using Stubby Screwdriver, Loosen Four
M4*10 Bolts to Check Transformer Voltage.
Transformer Replacement
Transformer Voltage Check
Version Date WA QA CA Note
00 Nov04 O O O

5. Electric Device
(CP-40)
5. Voltage Change and Check
5-1. 200V 10A Connected
5-2. 220V 10A Connected
Version Date WA QA CA Note
00 Nov04 O O O