CP40 service manual.pdf - 第89页
1. Head Part (CP-40) Version Date WA QA CA Note 00 Nov04 O O O <Adjustment Method> 1. Using Teaching Box, Move Head to Rear Acrylic Cover. 2. Loosen Four M3*6 Toras Screws on the Top of Head. 3. Pull Three Filters …

1. Head Part
(CP-40)
1. Click "Setup"=> "Diagnostics" => "Vacuum Pressure Level" in MMI.
2. Set Head 1~3 to ON.
3. Block Bottom of Comp Ass'y of Head with Finger and Verify Level Value.
When the Value is Under 560 [mmHg], Adjust it as follows.
560 [mmHg]
Version Date WA QA CA Note
00 Nov04 O O O
1-3-4. Vacuum Level Adjustment

1. Head Part
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
<Adjustment Method>
1. Using Teaching Box, Move Head to Rear Acrylic Cover.
2. Loosen Four M3*6 Toras Screws on the Top of Head.
3. Pull Three Filters on the Front.
4. Remove Head Cover.
2
3
Remove Four M3 * 6 4ea Toras.
Pull Three Vacuum Filter.
J6708006A
Remove Head Cover.
4

1. Head Part
(CP-40)
5. Adjust VR1 on I/F Board Until the Value is Over 560 [mmHg].
# Clockwise : Decrease Vacuum Level
Counterclockwise : Increase Vacuum Level
Decrease
Increase
Head I/F Board Ass'y
Version Date WA QA CA Note