CP40 service manual.pdf - 第165页

5. Electric Device (CP-40) 4. Materials Two Door Short Connectors(40) Added Material No. : J9080379A N o m e n c l a t u r e : D oor Short Connector Cable 50 Connect Door Short Connector to RDR_EN, FDR_EN. Housing : DF1B…

100%1 / 250
5. Electric Device
(CP-40)
Back Up Table Down Due to Door Lock Switch Shutoff When Door Open
Application Date Model Name Serial No. Remarks
AfterJul.1,2002 CP-40 Series CA-1150-B7 Non CE Type
AfterJul.1,2003 CP-40Series CA-1224-C7 Non CE Type
1.Purpose
When Opening Door for Feeder Replacement, Back Up Table may Get Down Due to Door Lock Switch Shutoff to Cause
Inconvenience of Work and Loss of Efficiency.
2.Application Scope
3. Control Part Modification
Classification Before After
Control
With Auto Run or with Stop Button
Pressed, Opening Door may Cause
All Operations to be Stopped and
Back Up Table Down.
- With Auto Run, Opening Door Causes All Stop.
- If Opening Door with Stop Button Pressed, X-Y Stops but
Back Up Table does not Get Down.
- If Pressing Start Button after Opening Door with Stop Button
Pressed, X-Y does not Move.
S/W
CP40 MMI Constants
- 16(Door Lock OPT) =>
0
CP40 MMI Constants
- 16(Door Lock OPT) =>
1
Version Data WA QA CA Note
00 04/11 O O O
5. Electric Device
(CP-40)
4. Materials
Two Door Short Connectors(40) Added
Material No. : J9080379A
Nomenclature : Door Short Connector Cable
50
Connect Door Short Connector
to RDR_EN, FDR_EN.
Housing : DF1B-2s-2.5R (2ea)
Terminal : DF1B-R24 (4ea)
Wire : RED
<Working Procedures>
1. Power OFF.
2. Connect Door Short Connector to FDR_EN, RDR_EN.
(FDR_EN is Located inside Control Panel.)
3. Setup => Input Password.
4. With MMI State, Input Password.
5. Click Constants.
6. Change "
0
" in 16(DOORLOCK_OPT) to "
1
".
Connection
Version Date WA QA CA Note
00 Nov04 O O O
5. Electric Device
(CP-40)
7. After Clicking OK to Save, Power OFF.
8. After Rebooting, Check Constants 16(DOORLOCK_OPT) is Set to "1" and Changed Information is Reflected through Testing.
Version Date WA QA CA Note
00 Nov04 O O O