CP40 service manual.pdf - 第51页

MODULE ERROR CODE Symptom and Cause ACTION Service Manual PMT Error Code Table $223, 0, "[Step Program] ", "Cycle=%d Head=%d " Width dX value of Fiducial Mark is incorrect. Width dX of Fiducial Mark s…

100%1 / 250
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$206, 1,
"[Step Program] ", "Cycle=%d Head=%d "
No. of Stick Unit is incorrect.
Stick Unit No. shall be 1~10.
$207, 1,
"[Step Program] ", "Cycle=%d Head=%d "
No. of Tray Unit is incorrect.
Tray Unit No. shall be 1~3.
Click <Tray Feeder> button of <Setup/PCB Setup(Feeder)>.
$208, 1,
"[Step Program] ", "Cycle=%d Head=%d "
No. of Tape Feeder is incorrect.
Tape Feeder No. shall be 1~52.
4-3-2
4-3-5
$209, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Stick No. is incorrect.
Stick No. shall be 1~10.
$210, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Tray No. is incorrect.
Tray No. shall be 1~5 (for Single Tray) and 1~20 (for Multi Tray).
$211, 1,
"[Step Program] ", "Cycle=%d Head=%d "
ANC No. is incorrect.
ANC No. shall be 1~4. 4-3-4
$212, 1,
"[Step Program] ", "Cycle=%d Head=%d "
ANC Hole No. is incorrect.
ANC Hole No. shall be 1~20 (for 20-hole ANC), 1~10 (for 10-hole ANC) and 1~2 (for Gripper ANC).
$213, 1,
"[Step Program] ", "Cycle=%d Head=%d "
ANC Type No. is incorrect.
Select the suitable ANC Type.
$214, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Skip Flag is incorrect.
Select the suitable Skip Flag.
Select the point to skip below SK in <Setup/PCB Setup(Step Program) and input Y to the point.
$215, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Fiducial Mark data is incorrect.
Select the suitable Fiducial Mark.
$216, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Fiducial Mark type is incorrect.
Select the suitable Fiducial Mark Type.
$217, 0,
"[Step Program] ", "Cycle=%d Head=%d "
X value of No. 1 Fiducial Mark is incorrect.
X value of No. 1 Fiducial Mark shall be in PCB area.
$218, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Y value of No. 1 Fiducial Mark is incorrect.
Y value of No. 1 Fiducial Mark shall be in PCB area.
$219, 0,
"[Step Program] ", "Cycle=%d Head=%d "
X value of No. 2 Fiducial Mark is incorrect.
X value of No.2 Fiducial Mark shall be in PCB area.
$220, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Y value of No. 2 Fiducial Mark is incorrect.
Y value of No.2 Fiducial Mark shall be in PCB area.
$221, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Length IX value of Fiducial Mark is incorrect.
Length IX value of Fiducial Mark shall be 0.1~10mm.
$222, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Length IY value of Fiducial Mark is incorrect.
Length IY value of Fiducial Mark shall be 0.1~10mm.
- 38 -
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
PMT Error
Code Table
$223, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Width dX value of Fiducial Mark is incorrect.
Width dX of Fiducial Mark shall be 0.1~10mm.
$224, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Width dY value of Fiducial Mark is incorrect.
Width dY of Fiducial Mark shall be 0.1~10mm.
$225, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Fiducial Mark scan speed is incorrect.
Fiducial Mark Scan speed shall be 1~100mm/s.
$226, 1,
"[Step Program] ", "Cycle=%d Head=%d "
Part(Feeder) is not defined.
Define Feeder Unit and Feeder No.
$228, 0,
"[Step Program] ", "Cycle=%d Head=%d "
Same (X, Y) coordinates exist between steps on Step-Program of PCB Setup.
Step-Program load is possible even if error occurs. But, modify the same coordinates in Step-
Program of PCB Setup because placement error can be occurred when actual placement.
$300,
$301, 1, 4-3-4
$309, 1,
"[ANC] ", "ANC=%d Hole=%d "
ANC type is incorrect.
Select the suitable ANC type.
(At this time, you should know how this PCB File is prepared initially.)
4-3-4
$311, 1,
"[ANC] ", "ANC=%d Hole=%d "
ANC Connect No. is incorrect.
ANC Connect No. shall be 1~4.
System not supplied with Option shall be 1~2.
4-3-2
$312, 1,
"[ANC] ", "ANC=%d Hole=%d "
Feeder station No. is incorrect.
Feeder Station No. shall be 1~2.
$313, 1,
"[ANC] ", "ANC=%d Hole=%d "
Feeder No. is incorrect.
Feeder No. shall be 1~52. 4-3-5
$314, 1,
"[ANC] ", "ANC=%d Hole=%d "
Nozzle type can not be matched to ANC type.
Adjust the Nozzle type to ANC type. 4-3-4
$1300, 4-3-4
$1302, 0, 4-3-4
$1303, 0,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
Y value of Nozzle position is incorrect.
Nozzle position Y value shall be in system area.
$1305, 0,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
Z value of Nozzle position is incorrect.
Move a Camera to hole of ANC concerned in Dialog Box displayed after executing the command of
<Setup/ANC Setting> of MMI, move down Z-axis of head concerned to Pickup position with teaching
box and click the <Get. Z> button.
$1315, 0,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
ANC is required.
Select the suitable ANC. 4-3-4
$400,
$401, 1,
"[ANC] ", "ANC=%d Hole=%d Head=%d "
X value of Nozzle position is incorrect.
Nozzle position X value shall be in system area.
"[Tape Feeder] ", "Station=%d Feeder=%d "
Feeder station No. is incorrect.
Feeder Station No. shall be 1(Front)~2(Rear).
"[ANC] ", "ANC=%d Hole=%d "
Nozzle type is incorrect.
Select the suitable Nozzle type.
- 39 -
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$402, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Feeder No. is incorrect.
Feeder No. shall be 1~76(for Tray Feeder) or 1~52(Stick Feeder). 4-3-5
$403, 1
"[Tape Feeder] ", "Station=%d Feeder=%d "
Feeder type is incorrect.
Use the suitable Feeder. 4-3-2
$406, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Z position is incorrect.
Z position shall be -10~15mm.
$407, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d "
R value of angle is incorrect.
Angle R value shall be degree of -360~+360.
$408, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Link station No. of Feeder is incorrect.
Link Station No. of Feeder shall be 1~2.
$409, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Link No. of Feeder is incorrect.
Link No. of Feeder shall be 1 ~ 52.
$410, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Linked to itselt or forming the loop is not allowable.
Link to other Feeder No.
$411, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Linked to other parts.
Link to Feeder using the same part.
$412, 1,
"[Tape Feeder] ", "Station=%d Feeder=%d "
Dump Box is incorrect.
Use the suitable Dump Box.
$1400,
$1404, 0,
$1405, 0,
"[Tape Feeder] ", "Station=%d Feeder=%d Head=%d "
Y value is incorrect.
Y value shall be in system area.
PMT Error
Code Table
$500,
$501, 1,
$502, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick No. is incorrect.
Stick No. shall be 1~10.
$506, 0,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Pickup height Z of Stick is incorrect.
Z position shall be -10~15mm.
$507, 0,
"[Stick Feeder] ", "Unit=%d Stick=%d "
R value of angle is incorrect.
Angle R value shall be degree of -360~+360.
$508, 1,
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick Unit link No. is incorrect.
Stick Unit Link No. shall be 1~10.
X value shall be in system area.
"[Stick Feeder] ", "Unit=%d Stick=%d "
Stick Unit No. is incorrect.
Stick Unit No. shall be 1~10.
"[Tape Feeder] ", "Station=%d Feeder=%d Head=%d "
X value is incorrect.
- 40 -