CP40 service manual.pdf - 第237页

12. Performance/Efficiency (CP-40) Version Date WA QA CA Note 00 Nov04 O O O 1. Check Feeder Operates in Semi-Pitch. (Pick Up Position Check) 2. Check Vinyl of Part Reel is Wound Properly. 3. Check Pick Up Height. 12-3-1…

100%1 / 250
12. Performance/Efficiency
(CP-40)
NO Symptom Possible Cause Error Code Action
Instructio
n
1
Bad Installation
Lack of Vacuum Volume
Remove Internal Foreign Material with Air Gun.
2 NozzlePickUpError
Replace O-Ring.
12-3-2
3 Part Pick Up Error
Check Feeder Pitch.
12-3-1
4
Part Installation Error
Check Comp Data.
12-3-3
5
Reset Camera Offset.
6
Reset Spindle Center.
12-3-7
7
Check Installation Speed of Test Parameter.
12-3-8
8
Check Part Setup Parameter.
9
50M Vision Recognition Error
Check 50M Vision Part Spec.
10
Set 50M Head3 Z-Axis Speed.
12-3-6
11
IT Malfunction
Communication Error Check LAN Card for Bad Connection.
12
Power Malfunction
Check Step Motor Driver 24V.
13
Check Power Supply Voltage(5V, 12V).
14
Check IQIF Controller Power.
15 Loading Error
MMI Program Loading Error Reset Soft_Ware.
12-3-9
16
17
18
12-2. Trouble Diagnosis
12. Performance/Efficiency
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
1. Check Feeder Operates in Semi-Pitch.
(Pick Up Position Check)
2. Check Vinyl of Part Reel is Wound Properly.
3. Check Pick Up Height.
12-3-1. Part Pick Up Error
Normal Semi-Pitch
Vinyl
Normal
Covered with Vinyl
If Pick Up Height is High, Part Size cannot be
Recognized due to the symptom shown in the
left-hand side. Align Score does not Reach 85.
12. Performance/Efficiency
(CP-40)
4.IntheDataonParts,VerifyPickUpSpeedandPickUpDelay.
Example) If Pick Up Speed = 2012: Pick Up Delay = 30 ~ 50 msec
Pick Up Speed: Fastest
If Pick Up Speed = 1608: Pick Up Delay >= 50 msec
If Pick Up Speed = 1005: Pick Up Delay >= 70 msec
Pick Up Speed = Middle
Absorption is Applicable to not Simultaneous Pick Up but Separate Pick Up.
5. Check the Inside of Nozzle is not Clogged.
; Clogged Nozzle may Affect Installation State and Pick Up.
Especially if Nozzle is Stained with Bond and Chips are not Removed, Pick Up Error Continues to be Occurred.
6. Check Ends of Nozzle are not Worn.
; Worn Nozzle may Cause Align Score to be Lower, Chips to be Blown off when Installing it and Pick Up Error Rate to be
Higher.
Version Date WA QA CA Note
00 Nov04 O O O