MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
Auto Sequence
Part
$4001
Pickup error when retrying (Head 1)
Retrying was given as much as repeated times caused by vacuum check error
when part pick-up.(Occurred when part fails to be picked up.)
Check part pickup position and Z-axis pickup height at PCB setup.
12-3-1
12-3-3
Auto Sequence
Part
$4002
Pickup error when retrying (Head 2)
Retrying was given as much as repeated times caused by vacuum check error
when part pick-up.(Occurred when part fails to be picked up.
$4003
Pickup error when retrying (Head 3)
Retrying was given as much as repeated times caused by vacuum check error
when part pick-up.(Occurred when part fails to be picked up.
12-3-1
$4011
Pickup error when retrying many times (Head 1)
Retrying was given as much as repeated times caused by vacuum check error
when part pick-up.(Occurred when part fails to be picked up.
Check part pickup position and Z-axis pickup height at PCB setup. 12-3-3
$4012
Pickup error when retrying many times (Head 2)
Retrying was given as much as repeated times caused by vacuum check error
when part pick-up.(Occurred when part fails to be picked up.
$4013
Pickup error when retrying many times (Head 3)
Retrying was given as much as repeated times caused by vacuum check error
when part pick-up.(Occurred when part fails to be picked up.
$4101
Nozzle is choked before picking-up (Head 1)
Nozzle is clogged when checking it before moving to Pickup position.
$4102
Nozzle is choked before picking-up (Head 2)
Nozzle is clogged when checking it before moving to Pickup position.
$4103
Nozzle is choked before picking-up (Head 3)
Nozzle is clogged when checking it before moving to Pickup position.
4-3-2
$4111
Nozzle is choked before ANC (Head 1)
Nozzle is clogged when checking it in Auto Nozzle Change.
4-3-4
$4112
Nozzle is choked before ANC (Head 2)
Nozzle is clogged when checking it in Auto Nozzle Change.
$4113
Nozzle is choked before ANC (Head 3)
Nozzle is clogged when checking it in Auto Nozzle Change.
$4201
Can't open ANC
Fails to open shutter of ANC in Auto Nozzle Change.
11-3-3
11-3-4
$4202
Can't close ANC
Fails to close shutter of ANC in Auto Nozzle Change.
11-3-5
$4500
The size of Fiducial Mark is too big
Larger Mark than size of Fiducial Mark registered is detected when inspecting
Fiducial Mark.
$4510
The length of Fiducial Mark is too long
Longer Mark than length of Fiducial Mark registered is detected when inspecting
Fiducial Mark.
Check that air pressure drops down below the standard values.
Check a nozzle for clogged conditions.
- 7 -
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$4520
Fiducial Mark can't be detected
Fiducial sensor fails to detect the Fiducial Mark when inspecting Fiducial Mark.
$4530
Many Fiducial Marks were detected
Other marks aside from Fiducial Mark registered are detected when inspecting
Fiducial Mark.
$45F0
Fiducial error was detected
Error occurs to Fiducial vision board.
$4601
Nozzle exists already in head, can't pick up another nozzle. (Head 1)
Message of "Nozzle exists already in Head" is shown. This alarm occurs when
trying to seize nozzle again with test pick, etc.
1-3-3
1-3-6
$4602
Nozzle exists already in head, can't pick up another nozzle. (Head 2)
Message of "Nozzle exists already in Head" is shown. This alarm occurs when
trying to seize nozzle again with test pick, etc.
4-3-2
Auto Sequence
Part
$4603
Nozzle exists already in head, can't pick up another nozzle. (Head 3)
Message of "Nozzle exists already in Head" is shown. This alarm occurs when
trying to seize nozzle again with test pick, etc.
Check that nozzle exists in a head concerned.
Remove foreign materials adhered to ALIGN GLASS.
1-3-3
1-3-6
$4611
Nozzle is in the head (SCT_VOPEN < VAC level) (Head 1)
Nozzle is in Head as results of checking the head condition with vacuum even after
putting nozzle on ANC with Test Put, etc.
$4612
Nozzle is in the head (SCT_VOPEN < VAC level) (Head 2)
Nozzle is in Head as results of checking the head condition with vacuum even after
putting nozzle on ANC with Test Put, etc.
4-3-2
$4613
Nozzle is in the head (SCT_VOPEN < VAC level) (Head 3)
Nozzle is in Head as results of checking the head condition with vacuum even after
putting nozzle on ANC with Test Put, etc.
$4621
Nozzle does not exist in the head (SCT_VCLOSE > VAC level) (Head 1)
Nozzle does not exist in Head as results of checking the head condition with
vacuum even after picking nozzle with Test Pick, etc.
$4622
Nozzle does not exist in the head (SCT_VCLOSE > VAC level) (Head 2)
Nozzle does not exist in Head as results of checking the head condition with
vacuum even after picking nozzle with Test Pick, etc.
4-3-2
$4623
Nozzle does not exist in the head (SCT_VCLOSE > VAC level) (Head 3)
Nozzle does not exist in Head as results of checking the head condition with
vacuum even after picking nozzle with Test Pick, etc.
$4651
Can't put a nozzle. A nozzle exists in ANC setting (Head 1)
Error occurred when message of "A nozzle already exists in the hole" was specified
already when trying to put nozzle on the hole defined by ANC.
Check that nozzle exists in ANC concerned. If existed, remove the nozzle manually. Then corrective
actions are to be given by confirming the cause of error.
Check that nozzle exists in a head concerned.
Remove foreign materials adhered to ALIGN GLASS.
Check data inputted to Fiducial Mark register screen.
Check that nozzle exists in a head concerned. If existed, remove the nozzle manually. Then
corrective actions are to be given by confirming the cause of error.
- 8 -
MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$4652
Can't put a nozzle. A nozzle exists in ANC setting (Head 2)
Error occurred when message of "A nozzle already exists in the hole" was specified
already when trying to put nozzle on the hole defined by ANC.
4-3-2
$4653
Can't put a nozzle. A nozzle exists in ANC setting (Head 3)
Error occurred when message of "A nozzle already exists in the hole" was specified
already when trying to put nozzle on the hole defined by ANC.
$4661
Can't pick up a nozzle, A nozzle does not exist in ANC setting (Head 1)
Error occurred when message of "A nozzle does not exist in the hole" was specified
already when trying to pick up nozzle from the hole defined by ANC.
$4662
Can't pick up a nozzle, A nozzle does not exist in ANC setting (Head 2)
Error occurred when message of "A nozzle does not exist in the hole" was specified
already when trying to pick up nozzle from the hole defined by ANC.
4-3-2
$4663
Can't pick up a nozzle, A nozzle does not exist in ANC setting (Head 3)
Error occurred when message of "A nozzle does not exist in the hole" was specified
already when trying to pick up nozzle from the hole defined by ANC.
$4801
Step selection is invalid
Error occurred when steps selected in Range selection or step selection of Array
PCB exceed total steps taught.
$4802
Cycle or Step selection is invalid
Error occurred when cycles or steps selected exceed total no. of cycles or steps of
PCB associated.
$4803
Mode selection is invalid
Occurs when trying to work with invalid mode in Placement Monitor.
Tray Feeder
Part
$5101
Out of components in the tray feeder unit #1[1]
Out of parts in PALLET of number in right [ ] of 20-stage Tray Feeder 1.
$5102
Out of components in the tray feeder unit #1[1]
Out of parts in PALLET of number in right [ ] of 20-stage Tray Feeder 1.
12-3-3
$5103
Out of components in the tray feeder unit #1[1]
Out of parts in PALLET of number in right [ ] of 20-stage Tray Feeder 1.
$5104
Out of components in the tray feeder unit #1[1]
Out of parts in PALLET of number in right [ ] of 20-stage Tray Feeder 1.
Tray Feeder
Part
$5105
Out of components in the tray feeder unit #1[1]
Out of parts in PALLET of number in right [ ] of 20-stage Tray Feeder 1.
$5106
Out of components in the tray feeder unit #1[1]
Out of parts in PALLET of number in right [ ] of 20-stage Tray Feeder 1.
Try again by reloading the PCB file after reset.
Check that nozzle exists in hole concerned in ANC. If existed, retry is to be given after removing the
nozzle.
Initialize x, y data of pallet concerned to 1, 1 in dialog box displayed after executing the command of
<Mount/Tray Check> in MMI after supplying a part newly.
Check that nozzle indication is shown to a hole which allows a head to take a nozzle from dialog box
displayed as result of executing the command of <Setup/ANC Setting> in MMI.