12. Performance/Efficiency (CP-40) 12-3-7. Aligner Offset Setting Method Problems 1. In order to Set Installation State, Adjust A ctual Data of Spindle Center and Camera Offset. -> It may be a Problem wh en ANC,1005 P…

100%1 / 250
12. Performance/Efficiency
(CP-40)
12-3-6.
50M Head3 Setting
=> Modify Data within Circles.
Version Date WA QA CA Note
00 Nov04 O O O 50M
12. Performance/Efficiency
(CP-40)
12-3-7.
Aligner Offset Setting Method
Problems
1. In order to Set Installation State, Adjust Actual Data of Spindle Center and Camera Offset.
-> It may be a Problem when ANC,1005 Pick Up.
2. For LV, CV and WA Installation Equipment, Head Offset should not be Adjusted in order to Set Installation State. Especially
for WA, Aligner Offset should be Used in order to compensate for Offset of Large Parts Caused by Short-focus Lens.
Causes
Even though Aligner Offset was Used to Set Installation State, Not X and Y of Aligner Offset but Spindle Center and camera
Offset were Used Inevitably in the Process of Applying Fine Pitch Algorithm of Quad.
Actions
Use Aligner Offset to Set Installation State.
Version Date WA QA CA Note
00 Nov04 O O O
12. Performance/Efficiency
(CP-40)
Aligner Offset Setting Method
Use Aligner Offset to Set
Installation State.
Fine Pitch Algorithm is not Used.
These Columns are not Used to
Set Installation State.
1. According to the Existing Method, Setup Spindle Center and Cameral Offset.
-. Spindle Center : Use Head Offset Calibration of Vision Calibration.
-. Camera Offset : Centering Head 1, Measure the Distance of Camera to Setup.
2. Aligner Offset Setting Method
-. Install 100 PIN QFP to Set up Aligner Offset.
-. Install 1608CHIP to Check Installation State.
-. If Installation State is out of Specifications, Modify Aligner Offset Gradually to Set Installation State.
Version Date WA QA CA Note
00 Nov04 O O O