4. Feeder Base & ANC (CP-40) If Selecting "Auto Position", the below Window is Appeared. Take Cursor on X and Y of Ref. Position (Display ) . In Teaching, Select X, Y Get (Display ) . Select "OK" …

4. Feeder Base & ANC
(CP-40)
In Fiducial Mark Window, Select "Scan Test" as Follows and Perform Test Repeatedly.
=> Perform Test Repeatedly until Scan Data of X and Y is within +-0.01mm(Display ).
Take Cursor on Pos 1(Display ).
In Teaching, Select "Move"(Display ) .
Select "OK" and then "Auto Position"(Display ).
Display 4
Display 1
Display 2
Display 3
Version Date WA QA CA Note
00 Nov04 O O O

4. Feeder Base & ANC
(CP-40)
If Selecting "Auto Position", the below Window is Appeared.
Take Cursor on X and Y of Ref. Position(Display ).
In Teaching, Select X, Y Get(Display ).
Select "OK" to Finish.
Select and Verify "Set as Master"(Display ).
After Closing the Window, Move to Each ANC Hole and Check it is Located Properly.
Display 1
Display 2
Display 3
Version Date WA QA CA Note
00 Nov04 O O O

4. Feeder Base & ANC
(CP-40)
4-3-5. Multi Cylinder Block Replacement
1
2
Toras
M4*8 4EA
J2101539 Cover-Feeder S/T(Front)
J2101864 Cover-Feeder S/T(Rear)
J7061004B CON PANEL F/R
1. Loosen Four M4*8 Toras Bolts to Disconnect Cover-Feeder
S/T from the Body.
2. Loosen Four M3*6 Toras Bolts to Disconnect Con Panel F/R
from the Body.
Toras
M3*6 4EA
Version Date WA QA CA Note
00 Nov04 O O O