CP40 service manual.pdf - 第218页

11. Utility (CP-40) 11-3-1. Utility Specification !! Configuration and Specification o f Equipment are as Follow s. If the Applied Utility is not Prepa red, Do not Install an d Test the Equipment. Version Date WA QA CA N…

100%1 / 250
11. Utility
(CP-40)
NO Symptom Possible Cause Error Code Action
Instructio
n
1
Trans Former Malfunction
Low Input Voltage Modify Disconnected Cable. 11-3-2
2 Noise Tighten Bolts on Main Power Connector. 11-3-2
3
Power Supply
24V is not Output. Modify Disconnected 24VG and 24VP. 5-3-2
4 Bad Stick Feeder 24V Perform Lining AC/DC. 5-3-2
5 Front AC Power Malfunction Modify Disconnected Cable. 5-3-2
6 When Checking I/O, 24V Down Modify CV CN 37 Pin. 5-3-2
7
Air Filter Malfunction
Foreign Materials in Main Air
Clean and Replace Main Filter.
11-3-5
8
Foreign Materials in Air Filter RemoveWaterfromAirFilter.
11-3-5
9
Drainer Tube Connector Check Connect Connector.
11-3-5
10
Bad Filter Element Replace Filter Element.
11-3-3
11
Bad Tubing and Fitting
Tube Disconnection Check Tube Disconnection.
11-3-3
12
Fitting Looseness Tighten or Replace Fitting.
11-3-5
13
Air Pressure Error
Air Pressure Gage Check
Check Air Pressure Gage Level.
11-3-4
14
Check Air Pressure Gage Connector for
Disconnection.
11-3-4
15
16
17
18
11-2. Trouble Diagnosis
11. Utility
(CP-40)
11-3-1. Utility Specification
!! Configuration and Specification of Equipment are as Follows. If the Applied Utility is not Prepared, Do not Install and Test the Equipment.
Version Date WA QA CA Note
00 Nov04 O O O
11. Utility
(CP-40)
!! Configuration and Specification of Equipment are as Follows. If the Applied Utility is not Prepared, Do not Install and Test the Equipment.
Version Date WA QA CA Note
00 Nov04 O O O