CP40 service manual.pdf - 第217页
11. Utility (CP-40) NO Symptom Possible Cause Error Code Action Instr uctio n 1 Trans Former Malfunction Low Input Voltage Modify Discon nected Cable. 11-3-2 2 Noise Tighten Bolts on Main Power Connector. 11 -3-2 3 Power…

11. Utility
(CP-40)
11-1. Trouble Diagnosis Guide Table
# Number Indicates Priority of Check Items.
Electricity Air Pressure
Trans Former Power Supply Air Filter Tubing and Fitting
CP Replacement
4
Power Supply Replacement
5
OP Panel SW Replacement
OP Panel SW Soldering Check
Lamp Replacement
3
Power Supply Cable Check
2
AC/DC Line Check
3 2
Cable Disconnection Check
4
Power Supply 24V Output Check
1
Main Power Input/Output Check
1
Circuit Break Check
5
Water Removal from Air Filter
1
Drainer Tube Connector Check
2
Filter Element Replacement
3
Tube Disconnection Check
1
Fitting Looseness Check
2
Parts
Symptom
Check and Action

11. Utility
(CP-40)
NO Symptom Possible Cause Error Code Action
Instructio
n
1
Trans Former Malfunction
Low Input Voltage Modify Disconnected Cable. 11-3-2
2 Noise Tighten Bolts on Main Power Connector. 11-3-2
3
Power Supply
24V is not Output. Modify Disconnected 24VG and 24VP. 5-3-2
4 Bad Stick Feeder 24V Perform Lining AC/DC. 5-3-2
5 Front AC Power Malfunction Modify Disconnected Cable. 5-3-2
6 When Checking I/O, 24V Down Modify CV CN 37 Pin. 5-3-2
7
Air Filter Malfunction
Foreign Materials in Main Air
Clean and Replace Main Filter.
11-3-5
8
Foreign Materials in Air Filter RemoveWaterfromAirFilter.
11-3-5
9
Drainer Tube Connector Check Connect Connector.
11-3-5
10
Bad Filter Element Replace Filter Element.
11-3-3
11
Bad Tubing and Fitting
Tube Disconnection Check Tube Disconnection.
11-3-3
12
Fitting Looseness Tighten or Replace Fitting.
11-3-5
13
Air Pressure Error
Air Pressure Gage Check
Check Air Pressure Gage Level.
11-3-4
14
Check Air Pressure Gage Connector for
Disconnection.
11-3-4
15
16
17
18
11-2. Trouble Diagnosis

11. Utility
(CP-40)
11-3-1. Utility Specification
!! Configuration and Specification of Equipment are as Follows. If the Applied Utility is not Prepared, Do not Install and Test the Equipment.
Version Date WA QA CA Note
00 Nov04 O O O