CP40 service manual.pdf - 第206页

9. Motor & Dr iver (CP-40) Version Date WA QA CA Note 00 Nov04 O O O < <Caution> - Short the above Selector T erminals. (Area to be Shorted: CONVEYOR WIDT H, SWING MIRROR, Z1 ~ Z6) - Connect Wiring Correctly…

100%1 / 250
9. Motor & Driver
(CP-40)
Motor Driver Cable Connection Check(General)
YC-R
Short
X
X
X
Short
X
YC-T
YM-R
YM-T
Y-U
Y-V
Y-W
Y-E
C
N
2
D
P
C
N
1
X
XC-R
Short
X
X
X
Short
X
XC-T
XM-R
XM-T
X-U
X-V
X-W
X-E
C
N
2
D
P
C
N
1
X
Z1C-R
Short
Z1C-T
Z1M-R
Z1M-T
Z1-U
Z1-V
Z1-W
Z1-E
C
N
2
D
P
C
N
1
Y X Z1 Z2 Z3
Short
X
X
X
X
X
Z2C-R
Short
Z2C-T
Z2M-R
Z2M-T
Z2-U
Z2-V
Z2-W
Z2-E
C
N
2
D
P
C
N
1
Short
X
X
X
X
X
Z3C-R
Short
Z3C-T
Z3M-R
Z3M-T
Z3-U
Z3-V
Z3-W
Z3-E
C
N
2
D
P
C
N
1
Short
X
X
X
X
X
Version Date WA QA CA Note
00 Nov04 O O O
9. Motor & Driver
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
<<Caution> - Short the above Selector Terminals.
(Area to be Shorted: CONVEYOR WIDTH, SWING MIRROR, Z1 ~ Z6)
- Connect Wiring Correctly not to Mix R,S,T Terminals with U,V,W,E Terminals.
=> Shorted Area is Used When CP-45, etc. Uses Regenerative Resistance.
=> When CP-40 Uses Linear Scale, Replace Motor Driver of X, Y according to the Following
Specification.
(For Z1, Z2 and Z3, Use the Same Spec. as LV.)
Short
9. Motor & Driver
(CP-40)
Motor Driver Cable Connection Check (for Linear Scale)
1. After Open the Right-hand Cover of Equipment, Check
if the Equipment is Linear Scale One or General One.
2. Check Wire and Sensor of Linear Scare for any
Normality.
Linear Scale
Side Cover Open
Version Date WA QA CA Note
00 Nov04 O O O LV+