CP40 service manual.pdf - 第205页

9. Motor & Dr iver (CP-40) Motor Driver Cable Connection Check(General) YC-R Short X X X Short X YC-T YM-R YM-T Y-U Y-V Y-W Y-E C N 2 D P C N 1 X XC-R Short X X X Short X XC-T XM-R XM-T X-U X-V X-W X-E C N 2 D P C N …

100%1 / 250
9. Motor & Driver
(CP-40)
9-3-1. Motor Driver Cable Check (PY Type)
1. Using Cross-head Screwdriver, Loosen Four Spherical Head Bolts to Open Rear Cover.
2.
Check Each Cable of Motor Driver(Y, X, Z1, Z2, Z3 from the Left).
3. Verify Nomenclatures and Standards.
Spherical Head Bolt
(for Securing Front Cover)
4ea
Motor Driver
Y X Z1 Z2 Z3
Y X Z1 Z2 Z3
Nomenclature PY0A0 50A PY0A0 30A PY0A0 15A PY0A0 15A PY0A0 15A
Standard IFCP01 IN51P01 IFD1P01 IFD1P01 IFD1P01
Version Date WA QA CA Note
00 04/11 O O O
9. Motor & Driver
(CP-40)
Motor Driver Cable Connection Check(General)
YC-R
Short
X
X
X
Short
X
YC-T
YM-R
YM-T
Y-U
Y-V
Y-W
Y-E
C
N
2
D
P
C
N
1
X
XC-R
Short
X
X
X
Short
X
XC-T
XM-R
XM-T
X-U
X-V
X-W
X-E
C
N
2
D
P
C
N
1
X
Z1C-R
Short
Z1C-T
Z1M-R
Z1M-T
Z1-U
Z1-V
Z1-W
Z1-E
C
N
2
D
P
C
N
1
Y X Z1 Z2 Z3
Short
X
X
X
X
X
Z2C-R
Short
Z2C-T
Z2M-R
Z2M-T
Z2-U
Z2-V
Z2-W
Z2-E
C
N
2
D
P
C
N
1
Short
X
X
X
X
X
Z3C-R
Short
Z3C-T
Z3M-R
Z3M-T
Z3-U
Z3-V
Z3-W
Z3-E
C
N
2
D
P
C
N
1
Short
X
X
X
X
X
Version Date WA QA CA Note
00 Nov04 O O O
9. Motor & Driver
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
<<Caution> - Short the above Selector Terminals.
(Area to be Shorted: CONVEYOR WIDTH, SWING MIRROR, Z1 ~ Z6)
- Connect Wiring Correctly not to Mix R,S,T Terminals with U,V,W,E Terminals.
=> Shorted Area is Used When CP-45, etc. Uses Regenerative Resistance.
=> When CP-40 Uses Linear Scale, Replace Motor Driver of X, Y according to the Following
Specification.
(For Z1, Z2 and Z3, Use the Same Spec. as LV.)
Short