bnp-b2365(eng)b.pdf - 第155页

3. Setup 3 - 68 M60S Series No. Abbrev . Parameter name Det ails Setting rang e (Unit) 3037 3038 3039 3040 taps 21 22 23 24 Synchronous tap switching spindle speed 2 Set the spindle rotation speed at which the step-2 acc…

100%1 / 399
3. Setup
3 - 67
M60S
Series
No.
Abbrev. Parameter name Details
Setting range
(Unit)
3021 sori
Orientation
rotation speed
Set the spindle orientation rotation speed.
Set the rotation speed for when the spindle rotates at the constant
rotation speed.
0 to 32767
(r/min)
3022 sgear
Encoder gear ratio Set the gear ratio of the spindle to the spindle end detector when the
spindle end detector feed back is directly input to NC.
0: 1/1
1: 1/2
2: 1/4
3: 1/8
3023 smini
Minimum rotation
speed
Set the minimum rotation speed of the spindle.
If an S command instructs the rotation speed below this setting, the
spindle rotates at the minimum rotation speed set by this parameter.
0 to 32767
(r/min)
3024 sout*
Spindle
connection
Set the type of the spindle to be connected.
0: No connection with the spindle
1: Serial connection (bus)
2 to 5: Analog output
0 to 5
3025 enc-on
Spindle end
detector
Set the spindle end detector connection destination.
0: No connection
1: NC
2: Drive unit
0 to 2
3026 cs_ori
Selection of coil in
orientation mode
0: Perform orientation using the coil selected when the orientation
command is issued.
1: Use coil L whenever the orientation command is issued.
0/1
3027 cs_syn
Selection of coil in
spindle
synchronous
mode
0: The coil H/L is selected by the actual spindle motor rotation speed
(calculated from commanded rotation speed) when spindle
synchronous control starts. (The coil is not switched during
synchronous control. The control is carried out with the coil selected
at start.)
If the actual spindle motor rotation speed is less than SP020, the coil
L is selected, and if more than the value, the coil H is selected.
1: Use coil H whenever the spindle synchronous command is issued.
0/1
3028 sprcmm
L system tap cycle
spindle forward
run/
reverse run M
command
Set the M code of the spindle forward run/reverse run command.
High-order three digits: The spindle forward run command's M code is
set.
Low-order three digits: The spindle reverse run command's M code is
set.
0 to 999999
3029 tapsel
Asynchronous tap
gear selection
Specify whether to use the tap rotation speed or maximum rotation
speed for the gear that is selected when an asynchronous tap command
is issued.
0: Tap rotation speed
1: Maximum rotation speed
This parameter is valid only when the M-function synchronous tap cycle
enable parameter (#1272 ext08/bit1) is ON.
0/1
3030 Not used. Set to "0". 0
3031
smcp_no *
Drive unit I/F
channel No.
(spindle)
Using a 4-digit number, set the drive unit interface channel No. and
which axis in that channel is to be used when connecting a spindle drive
unit.
High-order two digits : Drive unit interface channel No.
Low-order two digits : Axis No.
When using the conventional fixed layout, set all axes to "0000".
Set "0000" when using an analog spindle.
0000
0101 to 0107
0201 to 0207
3032
Not used. Set to "0". 0
Parameters with an asterisk * in the abbreviation, such as sout*, are validated with the NC power turned ON again.
3. Setup
3 - 68
M60S
Series
No.
Abbrev. Parameter name Details
Setting range
(Unit)
3037
3038
3039
3040
taps 21
22
23
24
Synchronous tap
switching spindle
speed 2
Set the spindle rotation speed at which the step-2
acceleration/deceleration time constant is to be switched at gear 00, 01,
10, or 11.
0 to 99999
(r/min)
3041
3042
3043
3044
tapt 21
22
23
24
Synchronous tap
switching time
constant 2
Set the time constant to reach synchronous tap switching spindle
rotation speed 2 (taps 21 to 24) at gear 00, 01, 10, or 11.
1 to 5000 (ms)
3045
3046
3047
3048
tapt 31
32
33
34
Synchronous tap
switching time
constant 3
Set the time constant to reach the maximum rotation speed (smax 1 to 4)
at gear 00, 01, 10, or 11.
1 to 5000 (ms)
3049 spt
Spindle
synchronization
acceleration/
deceleration time
constant
Set the acceleration/deceleration time constant for when the spindle
synchronization command's rotation speed changes during spindle
synchronous control.
0 to 9999 (ms)
3050 sprlv
Spindle synchro-
nization rotation
speed attainment
level
The spindle rotation speed synchronization complete signal will turn ON
when the difference of the reference spindle and synchronous spindle
actual rotation speeds is less than the level set for the synchronous
spindle rotation speed command value during spindle synchronous
control.
0 to 4095
(pulse)
(1 pulse =
0.088°)
3051 spplv
Spindle phase
synchronization
attainment level
The spindle phase synchronization complete signal will turn ON when
the phase difference of the reference spindle and synchronous spindle is
less than the set level during spindle phase synchronization control.
0 to 4095
(pulse)
(1 pulse =
0.088°)
3052 spplr
Spindle motor
spindle relative
polarity
Set the spindle motor and spindle's relative polarity.
Spindle CW rotation at motor CW rotation: Positive polarity Spindle CCW
rotation at motor CW rotation: Negative polarity
0: Positive
polarity
1: Negative
polarity
3053 sppst
Spindle end
detector
Z -phase position
Set the deviation amount from the spindle's reference position to the
spindle end detector's Z phase.
The deviation amount is obtained using the clockwise direction looking
from the front of the spindle as the positive direction.
0 to 359999
(1/1000°)
3054 sptc1
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 1
Set the spindle speed for changing the 1st step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3055 sptc2
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 2
Set the spindle speed for changing the 2nd step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3056 sptc3
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 3
Set the spindle speed for changing the 3rd step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3057 sptc4
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 4
Set the spindle speed for changing the 4th step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3058 sptc5
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 5
Set the spindle speed for changing the 5th step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3. Setup
3 - 69
M60S
Series
No.
Abbrev. Parameter name Details
Setting range
(Unit)
3059 sptc6
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 6
Set the spindle speed for changing the 6th step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3060 sptc7
Spindle synchro-
nization multi-step
acceleration/
deceleration
changeover
speed 7
Set the spindle speed for changing the 7th step's
acceleration/deceleration time constant.
0 to 99999
(r/min)
3061 spdiv1
Magnification for
time constant
changeover
speed 1
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
1 (sptc1) to the spindle synchronization multi-step acceleration/
deceleration changeover speed 2 (sptc2) as a magnification in respect to
the spindle synchronization acceleration/deceleration time constant
(spt).
0 to 127
3062 spdiv2
Magnification for
time constant
changeover
speed 2
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
2 (sptc2) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 3 (sptc3) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3063 spdiv3
Magnification for
time constant
changeover
speed 3
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
3 (sptc3) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 4 (sptc4) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3064 spdiv4
Magnification for
time constant
changeover
speed 4
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
4 (sptc4) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 5 (sptc5) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3065 spdiv5
Magnification for
time constant
changeover
speed 5
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
5 (sptc5) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 6 (sptc6) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3066 spdiv6
Magnification for
time constant
changeover
speed 6
Set the acceleration/deceleration time constant between the spindle
synchronization multi-step acceleration/deceleration changeover speed
6 (sptc6) to the spindle synchronization multi-step
acceleration/deceleration changeover speed 7 (sptc7) as a
magnification in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3067 spdiv7
Magnification for
time constant
changeover
speed 7
Set the acceleration/deceleration time constant for the spindle
synchronization multi-step acceleration/
deceleration changeover speed 7 (sptc7) and higher as a magnification
in respect to the spindle synchronization acceleration/deceleration time
constant (spt).
0 to 127
3068 symtm1
Phase
synchronization
start confirmation
time
Set the time to confirm that synchronization is attained before phase
synchronization control is started.
When "0" is set, the time will be 2 seconds. When "100" or less is set,
the time will be 100ms.
0 to 9999 (ms)
3069 symtm2
Phase
synchronization
end confirmation
time
Set the time to wait for phase synchronization control to end as the time
for the rotation speed to reach the attainment range.
When "0" is set, the time will be 2 seconds. When "100" or less is set,
the time will be 100ms.
0 to 9999 (ms)
3070 syprt
Phase
synchronization
speed
Set the fluctuation amount to change the synchronous spindle rotation
speed during phase synchronization control as the command speed and
rate.
When "0" is set, the amount will be 100%.
0 to 100 (%)
3071 (Not used.) Not used. Set to "0". 0