1. Installation
1 - 11
1-3-2 Installation direction and clearance
Wire each unit in consideration of the maintainability and the heat dissipation, as well as secure
sufficient space for ventilation.
100mm or
more
100mm or
more
10mm
or
more
100mm or
more
100mm or
more
50mm
or more
100mm or
more
100mm or
more
75mm or more
50mm
or more
10mm
or
more
CAUTION
The ambient temperature condition for the power supply unit or the drive units is
55°C or less. Because heat can easily accumulate in the upper portion of the
units, give sufficient consideration to heat dissipation when designing the panel.
If required, install a fan in the panel to agitate the heat in the upper portion of the
units.
1-3-3 Prevention of entering of foreign matter
Treat the cabinet with the following items.
Make sure that the cable inlet is dust and oil proof by using
packing, etc.
Make sure that the external air does not enter inside by
using head radiating holes, etc.
Close all clearances.
Securely install door packing.
If there is a rear cover, always apply packing.
Oil will tend to accumulate on the top. Take special
measures such as oil-proofing to the top so that oil does
not enter the cabinet from the screw holds.
After installing each unit, avoid machining in the periphery.
If cutting chips, etc., stick onto the electronic parts, trouble
may occur.
When using the unit in an area with toxic gases or high
levels of dust, protect the unit with air purging (system to
blow clean air so that the panel's inner pressure is higher
than the outer pressure).
1. Installation
1 - 12
1-3-4 Panel installation hole work drawings (Panel cut drawings)
Prepare a square hole to match the unit width.
[Unit: mm]
Square
hole
(Note 1)
342
360
52
2-M5 screw
342
360
82
2-M5 screw
Square hole
(Note 1)
342
360
112
2-M5 screw
Square hol e
(Note 1)
342
360
142
4-M5 screw
60
Square hol e
(Note 1)
Unit width: 60mm (only with fin)
Unit width: 90mm
Unit width: 120mm Unit width: 150mm
POINT
1. Attach packing around the square hole to provide a seal.
2. A square hole does not need to be machined on the MDS-C1-V1-10 or
smaller, MDS-C1-V2-1010 or smaller and MDS-C1-SP-15 or smaller units.
1. Installation
1 - 13
1-3-5 Heating value
Each heating value is calculated with the following values.
The values for the servo drive unit are for a stall output, and the values for the spindle drive unit are for
a continuous rated output. The value for the power supply unit includes the AC reactor's heating value.
Servo drive unit Spindle drive unit Power supply unit
Heating amount
[W]
Heating amount
[W]
Heating amount
[W]
Heating amount
[W]
Type
MDS-C1-
Inside
panel
Outside
panel
Type
MDS-C1-
Inside
panel
Outside
panel
Type
MDS-C1-
Inside
panel
Outside
panel
Type
MDS-C1-
Inside
panel
Outside
panel
V1- 01 21 0 V2-0101 38 0 SP- 04 30 0 CV- 37 21 34
V1- 03 27 0 V2-0301 41 0 SP- 075 40 0 CV- 55 23 42
V1- 05 37 0 V2-0303 43 0 SP- 15 49 0 CV- 75 25 55
V1- 10 53 0 V2-0501 46 0 SP- 22 26 42 CV-110 26 99
V1- 20 25 66 V2-0503 52 0 SP- 37 28 51 CV-150 29 126
V1- 35 30 102 V2-0505 62 0 SP- 55 31 76 CV-185 33 162
V1- 45S 34 124 V2-1005 78 0 SP- 75 35 102 CV-220 35 175
V1- 45 37 148 V2-1010 96 0 SP-110 41 140 CV-260 40 220
V1- 70S 38 151 V2-2010 37 117 SP-150S 48 140 CV-300 46 274
V1- 70 50 234 V2-2020 41 137 SP-150 48 187 CV-370 54 346
V1- 90 56 275 V2-3510S 44 146 SP-185 62 280
V1-110 74 392 V2-3510 42 148 SP-220 65 301
V1-150 96 545 V2-3520S 48 165 SP-260 80 403
V2-3520 45 168 SP-300 98 522
V2-3535 51 209
V2-4520 52 214
V2-4535 57 249
V2-4545S 55 225
V2-4545 64 295
V2-7035 70 336
V2-7045 77 382
V2-7070S 65 300
V2-7070 90 468
V2-9090S 65 300
POINT
Design the panel's heating value taking the actual axis operation (load rate) into
consideration. With a general machine tool, the servo drive unit's load rate is
approx. 50%, so the heating values inside the panel are half the values shown
above. (Excluding the power supply and spindle drive unit.)
When using MDS-C1-CV-260, MDS-C1-SP[]-185 and MDS-C1-V2-3535
Total heating value = (40 + 220) + (62 + 280) + (51 + 209) = 862 [W]
Heating value in panel = (40) + (62) + (51 × 0.5) = 127.5 [W]
(Example 1)