System Manual lñÑçêÇ=fåëíêìãÉåíë=mä~ëã~=qÉÅÜåçäçÖó== mä~ëã~ä~Ä póëíÉã=NMM
PKQ= VQJNMMJPJQN`=f`m=NUM=ÅÜ~ãÄÉê=âáí=ïáíÜ=Ö~íÉ=î~äîÉ=
The ICP chamber kit comprises the following components:
Process chamber.
Pumping port isolation valve and automatic pressure controller suitable for use with a
turbomolecular pump.
The ICP process chamber, shown in Fig 3.2, is machined from a single aluminium block with
the minimum number of O-rings to provide the highest vacuum integrity.
SLIT VALVE
SLIT VALVE
O-RING
LOCATING
PIN
VIEW
PORT
BLANKIN
G
PLATE
Cartridge heater (if fitted)
Inserted into a hole in the
chamber base (one in each
corner)
Fig 3.2: 94-100-3-41C process chamber
The chamber is fitted with the following ports:
a) Single view port fitted with an RF shield for viewing the plasma. Note that the view
port is mounted on a blanking plate, which can be removed to provide access to the
chamber interior.
b) Pumping port.
c) Wafer transfer port to which is attached a pneumatically operated gate valve.
d) Wafer clamp port.
e) Process gas inlet port.
f) Two ports for the connection of vacuum measurement components.
The pneumatically operated gate valve, for connecting to the selected wafer insertion device,
is attached to the chamber by six claw bolts and is positioned by two locating pins (dowels).
Sealing is provided by a rectangular O-ring.
Description
Printed: 22-Mar-06, 7:29 Page 3-7 of 22 UC Davis 94-721001 Issue 1: March 06

mä~ëã~ä~Ä póëíÉã=NMM lñÑçêÇ=fåëíêìãÉåíë=mä~ëã~=qÉÅÜåçäçÖó== System Manual
PKQKN= VQJNMMJPJMMLONm=mêçÅÉëë=ÅÜ~ãÄÉê=ÉäÉÅíêáÅ~ä=ÜÉ~íáåÖ=âáí=
The electrical heating kit comprises four cartridge heaters; inserted into holes at the corners
in the base of the process chamber, see Fig 3.2. Heater control is via a unit mounted on the
console, where the temperature can be set manually. A temperature in the range 50ºC to
60ºC is recommended for most processes.
WARNING
IF THE PROCESS CHAMBER TEMPERATURE IS SET TO A VALUE ABOVE 60ºC, CONTACT
WITH IT CAN CAUSE BURNS.
BEFORE OPERATING THE CHAMBER ABOVE 60ºC, ENSURE THAT EXTERNAL HEAT
SHIELDS ARE FITTED.
PKQKO= VQJNMMJPJMMLMR=OMMãã=mìãéÇçïå=éáéÉ=ÜÉ~íÉê=âáí=
This heating kit is applied to the pump-down pipe to give optimum vacuum performance and
to minimise the deposition of loosely adherent material, which might generate particulates.
Description
UC Davis 94-721001 Issue 1: March 06 Page 3-8 of 22 Printed: 22-Mar-06, 7:29

System Manual lñÑçêÇ=fåëíêìãÉåíë=mä~ëã~=qÉÅÜåçäçÖó== mä~ëã~ä~Ä póëíÉã=NMM
PKR= VQJNMMJRJNO^=`êóç=L=ÜÉ~íÉÇ=ÓNRMLQMM`=ÜÉäáìãJ~ëëáëíÉÇ=äçïÉê=
ÉäÉÅíêçÇÉ=
The helium-assisted lower electrode, shown in Fig 3.3, is fabricated from aluminium. The
electrode is fitted with an integral dark space shield.
The lower electrode is heated by an embedded 1250W element and cooled by liquid nitrogen
flowing through embedded tubing.
t~ÑÉê=äáÑí=
The wafer is lifted clear of the table (15mm) for transferring into a load lock or transfer
chamber by the wafer lift assembly. Compressed air flowing into the air cylinder forces its
piston and plunger upwards. The plunger contacts the base of the bellows which is connected
to a push rod. The 3-pin wafer support, mounted on top of the push rod, rises lifting the
wafer clear of the table. The push rod is lowered by the force exerted by the return spring.
t~ÑÉê=Åä~ãé=
The wafer clamp comprises a clamping ring attached to a lifting mechanism, and a clamping
plate. The clamping plate, attached to the clamping ring via three pillars and screws,
comprises an aluminium annulus with a quartz circular insert.
The wafer clamp is raised and lowered by two air cylinders, attached to the outside of the
process chamber; one located at each side of the wafer clamp. The piston of each air cylinder
is attached to a push rod, which passes through the base of the process chamber. Within the
process chamber, a circular plate mounted on the top of the push rod, is attached to the
wafer clamp by three M5 setscrews and compression springs. Rotating the setscrews changes
the compression of the springs and consequently the clamping force exerted on the wafer.
See Section 6 for the clamping force adjustment procedure.
Note that clamping plates are available with inserts for various sized wafers. Before loading a
wafer into the process chamber, ensure that the correct clamping plate is fitted. See Section 6
for the clamping plate changeover procedure.
q~ÄäÉ=íçé=éä~íÉ=
In some systems, the table top plate is fixed to the table by a ring of cap-head bolts. If your
system has a table of this type, refer to the following text and note.
The bolt heads are concealed behind screw covers, which require a special tool (supplied with
the system) for removal. (Tool part number: MD91D21726.)
NOTES:
1) When re-fixing the table top, do not over-tighten the bolts which will cause
the table top to bow. Check with a straight edge after tightening: if the table
top is not flat, release the bolt tensions until it is.
2) The screw covers (MD91D21723) are aluminium. When removing the covers,
it is recommended to use a little iso-propyl alcohol (IPA) to prevent the
thread from jamming.
eÉäáìã=Ä~ÅâáåÖ=
The purpose of helium backing is to set the temperature of the wafer close to that of the
temperature-controlled table by heat transfer. Helium is fed from a number of small holes in
the table underneath the wafer (which is clamped to the table) from where it flows radially
Description
Printed: 22-Mar-06, 7:29 Page 3-9 of 22 UC Davis 94-721001 Issue 1: March 06