FK-9F98-05 CP-643E Training Text for Service Engineers
Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [16/28]
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
Technical Support Div. Section No.2
5-
16
5.17 Loader System Sensor Positions
1. Refer to Fig. 27 for sensor locations along the loader system.
<Carrier Sensors>
1. Carrier retract end sensor 3.Carrier claw close- end sensor
2. Carrier claw open-end sensor 4. Carrier advance end sensor
<IN Carrier>
<OUT Carrier>
1
2 3
2
3
1
2
2
3
3
<Carrier at advance position>
2
2
2
2
3
3
3
3
4
4
<Carrier at retract position>
Figure 27
FK-9F98-05 CP-643E Training Text for Service Engineers
Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [17/28]
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
Technical Support Div. Section No.2
5-
17
5.18 Advance / Retract End Sensor Adjustment
1. Adjust the Advance and Retract End sensor height so the clearance between the top of the
sensor and dog is 1mm.
2. Align the center of the sensor with the dog in the X and Y directions.
<I/O Standard IN>
LX01C In-carrier Forward Limit Check LX03C Out-carrier Forward Limit Check
LX01D In-carrier Retract Limit Check LX03D Out-carrier Retract Limit Check
5.19 Claw Closed-End Sensor Adjustment
1. Close the carrier claws to turn the sensor ON. Move the sensor 1mm toward the ON position
and secure.
2. Align the center of the sensor with the dog in the X- direction.
As for the height, be careful to avoid any interference with the flag and sensor when opening
and closing the carrier claws.
<I/O Standard IN>
LX040 In-carrier Retract Limit Clamp Check (Fixed Rail)
LX041 In-carrier Retract Limit Clamp Check (Adjustable Rail)
LX042 In-carrier Forward Limit Clamp Check (Fixed Rail)
LX043 In-carrier Forward Limit Clamp Check (Adjustable Rail)
LX048 Out-carrier Retract Limit Clamp Check (Fixed Rail)
LX049 Out-carrier Retract Limit Clamp Check (Adjustable Rail)
LX04A Out-carrier Forward Limit Clamp Check (Fixed Rail)
LX04B Out-carrier Forward Limit Clamp Check (Adjustable Rail)
1mm
Figure 28
Figure 29
FK-9F98-05 CP-643E Training Text for Service Engineers
Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [18/28]
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
Technical Support Div. Section No.2
5-
18
5.20 Claw Open -End Sensor Adjustment
1. Set the carrier at the retract position.
2. Set the length of the cylinder rod to 9mm. (Retract position only)
3. Align the cylinder bolt with the center of the Open-Close lever.
4. Open the carrier claws. Find the edge of the sensor ON position and move the
sensor 0.5mm in the ON direction and secure.
<I/O Standard IN>
LX044 In-carrier Retract Limit Unclamp Check (Fixed Rail)
LX045 In-carrier Retract Limit Unclamp Check (Adjustable Rail)
LX046 In-carrier Forward Limit Unclamp Check (Fixed Rail)
LX047 In-carrier Forward Limit Unclamp Check (Adjustable Rail)
LX04C Out-carrier Retract Limit Unclamp Check (Fixed Rail)
LX04D Out-carrier Retract Limit Unclamp Check (Adjustable Rail)
LX04E Out-carrier Forward Limit Unclamp Check (Fixed Rail)
LX04F Out-carrier Forward Limit Unclamp Check (Adjustable Rail)
9mm
Open-close lever
Figure 30