CP643E.pdf - 第85页
FK-9F98-05 CP- 643E Training Text for Service Engineers Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [ 22 / 28 ] Fuji Machine Mfg. Co., Ltd. Okazaki SMT Equipment Quality Assurance Dept. Technical Support Div. S…

FK-9F98-05 CP-643E Training Text for Service Engineers
Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [21/28]
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
Technical Support Div. Section No.2
5-
21
8. Set the IN PCB clearance check sensor switch to “D_ON”, and both the arrival and speed
reduction sensor switches to “L_ON”.
Figure 32
Figure 33
5mm
15mm
(220mm)
(2
nd
PCB)
No Gap
No Gap
2
nd
PCB Stopper
(220mm)
(1
st
PCB)
1
st
PCB Stopper
1
st
PCB Stopper
Sensor positioning bolt for the 1
st
PCB
Sensor positioning bolt for the 2
nd
PCB
Stopper and Sensor Position
ing
for the IN conveyor.

FK-9F98-05 CP-643E Training Text for Service Engineers
Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [22/28]
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
Technical Support Div. Section No.2
5-
22
<<IN Carrier Sensor Adjustment>>
1. Load two PCBs on the IN carrier. “X0B1” (In carrier 1 detection check), “X0B2” (IN carrier 2
detection check) shall come ON when “Y074”, (In carrier advance) is ON. Adjust the sensor
position 5mm from the leading edge of each board. Ensure that the sensor switch is set to
“L_ON”. And make sure that the volume is at MAX position.
(1
st
PCB)
5mm
(2
nd
PCB)
5mm
IN Carrier
Sensor Positioning for the IN Carrier
Figure 34

FK-9F98-05 CP-643E Training Text for Service Engineers
Edition 5.0 Chapter 5. Loader and Conveyor Adjustment [23/28]
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
Technical Support Div. Section No.2
5-
23
<<OUT Carrier Sensor Adjustment>>
Adjust the sensors for the OUT carrier as follows:
1. Load 2 PCBs on the IN carrier. Advance the carrier to the forward end position. (Continued from
the IN carrier adjustment.). Move the XY table to the IN loading position. (Do NOT raise the Z-
axis.)
2. Turn ON I/O, “Y044” (Main clamp open). Manually raise Z to the IN loading position.
3. Turn ON “Y043” (Main clamp close) and “Y073”,(IN carrier open). Lower the Z-axis to the “Z0”
position to load 2 PCBs onto the XY table.
4. Turn ON “Y082” (Out carrier close), “Y084” (Out carrier advance), and “Y083”(Out carrier open)
so that Z-axis raise to the OUT loading position.
5. Turn ON “Y082”(Out carrier close) and “Y082” (Main clamp open). Lower Z to set to the same
condition as when the 2 PCBs were loaded on the IN carrier.
6. Adjust the sensor position so that “X0CC” (Out carrier 1 detection check), and “X0CD” (Out
carrier 2 detection check) are set 5mm from the leading edge of each Pcb. Set the sensor
switch to “L_ON”. And make sure that the volume is at MAX position.
(1
st
PCB)
5mm
(2
nd
PCB)
5mm
OUT Carrier
Sensor Position
ing
for the Out Carrier
Figure 35