cp45ref.pdf - 第108页
Samsung Component Placer CP-45F(V)/FS Refer ence Manual 2-54 H/ W o r S/W d ef ec t [Solution] Please contact our C/S. $e001 At PC = %x Addr = %x, err or of dividing b y 0 occurred. [Problem] S/W defect [Solution] Please…

System Messages of the MMI and Solutions
2-53
The DPRAM board is bad
Communication error occurred during the communication between the MMI and the
VME
[Solution]
Replace the DPRAM board
Please contact our C/S.
$d110 Received undefined command from the MMI.
[Problem]
The DPRAM board is bad
The versions of MMI and the VME are incompatible
Communication error occurred during the communication between the MMI and the
VME
[Solution]
Replace the DPRAM board
Check the versions of the MMI and the VME and use the correct version.
Please contact our C/S.
$d111 Received undefined communication command from the MMI.
[Problem]
The DPRAM board is bad
The versions of the MMI and the VME are incompatible
Communication error occurred during the communication between the MMI and the
VME
[Solution]
Replace the DPRAM board
Check the versions of the MMI and the VME and use the correct version.
Please contact our C/S.
$e000 At PC=%x, an access fault error occurred while the %x address was to be used.
[Problem]

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-54
H/W or S/W defect
[Solution]
Please contact our C/S.
$e001 At PC = %x Addr = %x, error of dividing by 0 occurred.
[Problem]
S/W defect
[Solution]
Please contact our C/S.
$e011 Access fault occurred in the vision board.
[Problem]
Vision board defect
[Solution]
Please contact our C/S.
Replace the board
$e012 Access fault occurred in the IO board.
[Problem]
IO board defect
[Solution]
Please contact our C/S.
Replace the board
$e013 Access fault occurred in the DPRAM board.
[Problem]
DPRAM board defect
[Solution]
Please contact our C/S.
Replace the board

System Messages of the MMI and Solutions
2-55
$e014 Access fault occurred in the Axis1 board.
[Problem]
Axis1 board defect
[Solution]
Please contact our C/S.
Replace the board
$e015 Access fault occurred in the Axis2 board.
[Problem]
Axis2 board defect
[Solution]
Please contact our C/S.
Replace the board
$e016 Access fault occurred in the Axis3 Board.
[Problem]
Axis3 board defect
[Solution]
Please contact our C/S.
Replace the board
$e017 Access fault occurred in the Axis4 board.
[Problem]
Axis4 board defect
[Solution]
Please contact our C/S.
Replace the board
$e100 %x error occurred in the IO board %d .
[Problem]