cp45ref.pdf - 第80页

Samsung Component Placer CP-45F(V)/FS Refer ence Manual 2-26 [Problem] No nozzle is in the head. [Solution] Check the ANC setting. $6030 Nozzle in the head. Can't put. [Problem] Checking after putting the nozzle rev…

100%1 / 149
System Messages of the MMI and Solutions
2-25
[Problem]
In the component data, there is no nozzle related setting.
[Solution]
Set the nozzle in the component data.
$600d Can't find the nozzle ID to use automatically
[Problem]
The nozzle specified in the component is not in the ANC.
[Solution]
Set the ANC again.
$600e Can't find the nozzle ID to use automatically
[Problem]
The nozzle specified in the component is not in the ANC.
[Solution]
Set the ANC again.
$600f Incorrect nozzle length.
[Problem]
Incorrect nozzle length is registered.
[Solution]
Check the nozzle length of the System.
$6010 Z axis can't move to the position of the nozzle check sensor.
[Problem]
The position of nozzle inspection is set incorrectly.
[Solution]
Check the setting of the nozzle inspection position of the System.
$6020 Can't put, no nozzle in the head.
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-26
[Problem]
No nozzle is in the head.
[Solution]
Check the ANC setting.
$6030 Nozzle in the head. Can't put.
[Problem]
Checking after putting the nozzle reveals there is a nozzle in the head
[Solution]
Check the Z axis height in the ANC.
Check the operation of the nozzle check sensor.
$6040 Z axis couldn't move to the put position.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$6050 Z axis couldn't move to a safe height after putting.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$6060 Can't get, nozzle in the head.
[Problem]
Can't get a nozzle because there is a nozzle in the head.
[Solution]
Check the ANC setting
Check the nozzle check sensor.
System Messages of the MMI and Solutions
2-27
$6070 No nozzle in the head. Can't get.
[Problem]
Checking after executing nozzle get reveals there is no nozzle in the head
[Solution]
Check the position in the ANC.
Check the operation of the nozzle check sensor.
$6080 Z axis couldn't move to the get position.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$6090 Z axis couldn't move to a safe height after getting.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$60a0 NOZZLE_EMPTY_ERROR.
$60b0 NOZZLE_EXIST_ERROR.
$60c0 SET_NOZZLE_POINT_ERROR.
$6501 Can't open the mirror.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$6502 Can't open the ANC.